Sunpak® Infrared Heaters
15
3.
Press
and
release
the
learn
button
on
the
heater
control.
Press
the
<ON>
button
on
the
wireless
device
within
10
seconds.
Make
sure
the
remote’s
red
indicator
light
went
on
while
pressing
the
remote.
4.
The
heater
should
now
recognize
the
wireless
device.
a.
Press
the
<OFF>
button
on
the
wireless
device
b.
Press
the
<ON>
button
c.
Press
the
<HI>
button
d.
Leave
heater
on
HI
for
first
5
minutes
If
the
heater
does
not
light,
repeat
procedure
4..
It
is
likely
that
there
is
still
air
in
the
gas
line.
If
the
heater
fails
to
light
or
fails
to
stay
lit
after
several
tries,
it
may
be
necessary
to
purge
the
air
from
the
gas
line
using
safe
practices.
Sunpak Pilot
The two electrodes near the pilot provide for
flame ignition and sensing. It is important that
these electrodes be position properly.
•
Electrodes should be located 3/16”from the
pilot hood and within the flame zone.
•
Electrodes must be spaced at least 3/8”
from each other to avoid spark from
grounding to the sensing electrode.
•
The ‘L’ shaped electrode should always be
used for sensing