EVERGEN M SERIES USER MANUAL
ASSEMbLy
14
Sol by Sunna Design | 990 Biscayne Boulevard, Office 701, Miami, FL 33132, USA | 1.800.959.1329 | [email protected]
L
!GREASE!
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:16
A
EVERGEN MANUAL IMAGES
11 OF 13
82064
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
PROPRIETARY
COPYRIGHT © 2012 ALL RIGHTS RESERVED. NO
PART OF THIS
DOCUMENT MAY BE REPRODUCED
STORED IN A
RETRIEVAL SYSTEM, OR
TRANSMITTED IN ANY
FORM
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
9/08/15
05/27/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
82064
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
6. Connect Solar Panel and Fixture Cables to the EMS
1
Route the two (2) unconnected solar panel cables into battery box with enough slack to easily connect to
the EMS.
2
Route the end of the fixture cable that has a two (2) position connector and ring terminal into the battery
box with enough slack to easily connect to the EMS. For systems with two fixtures, repeat for the second
fixture cable while using the fixture splitter adapter.
3
Take the ground wire from the EMS and place it onto the grounding lug followed by the ground wire from
the fixture cable.
4
Thread supplied 1/4"-20 nut onto ground lug grease and tighten to 5 ft-lbs (64 in-lbs).
GROUND
LUG
EMS
GROUND
WIRE
FIXTURE
2-POSITION
CONNECTOR
GROUND
WIRE
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
TITLE
B
1:16
A
EVERGEN MANUAL IMAGES
12 OF 13
82064
SHEET
SIZE
REVISION
SCALE
DRAWING NO
CAD REFERENCE
250 Bay Street
Victoria, BC Canada V9A 3K5
Tel [250] 380-0052
Fax [250] 380-0062
CHANGES SHALL BE INCORPORATED
ELECTRONICALLY BY THE DESIGN AUTHORITY
PDM MAINTAINED DATA
COPYRIGHT © 2012
ALL RIGHTS RESERVED. NO PART OF THIS
DOCUMENT MAY BE REPRODUCED STORED IN A
RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY
FORM,
PROPRIETARY
ORIGINALLY DESIGNED BY
ORIGINALLY DRAWN BY
CHECKED BY
DATE
DATE
DATE
Ben Jolie
Ben Jolie
9/08/15
05/27/2017
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
INTERPRET DIMENSIONS AND TOLERANCES
PER ASME Y14.100-2000
TOLERANCES APPLY AS SHOWN BELOW
DECIMALS SURF FINISH ANGLES
.X
.XX
.XXX
.XXXX
± .1
± .01
± .005
± .0005
63
1
INCHES
THIRD ANGLE PROJECTION
DOC #
DATE
21/12/11
57012
B
DOC REVISION
82064
ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT, CERTIFICATE REQUIRED WITH INITIAL SHIPMENT
!GREASE!
DO NOT CONNECT SOLAR PANELS
TO THE EMS AT THIS TIME.
C
CAUTION
AUTION