background image

Installation Steps

1.  Mount Illuminator

2.  Connect Illuminator to low voltage  

power supply 

3.  Input 12-24V DC/ 24V AC 

Optional Set-up (if required)

4.  Adjust Power to alter light intensity

5.  Adjust Photocell sensitivity

 

6.  Photocell following contact 

RM/RL F AI 200 Setup

7.  Telemetry input and photocell 

following contact

Set Up Steps

1. Position illuminator adjacent to 

camera and point towards scene 

2. Adjust vertical and horizontal  po-

sition of lamp to ensure full field  

of view illuminated

3. Tighten all fixings

Package Contents

1. Illuminator including mounting 

bracket 

(RM/RL F AI 200 only, includes 

additional wiring loom)

Adaptive Illumination (AI) Installation Guide

RAYMAX / RAYLUX  

FUSION AI illuminator

Overview

This installation guide provides instructions for installing the RAYMAX  

and RAYLUX DOUBLe FUSION 

AI” series illuminators

DOUBLE FUSION

GOLDeN RULeS:

•  Ensure operating voltage is 

correct for unit being installed 

(12-24V DC/ 24V AC)

Ve

rs

io

n:

 4

Summary of Contents for RAYMAX DOUBLE FUSION AI Series

Page 1: ...nd point towards scene 2 Adjust vertical and horizontal po sition of lamp to ensure full field of view illuminated 3 Tighten all fixings Package Contents 1 Illuminator including mounting bracket RM RL...

Page 2: ...following contact RM RL F AI 200 1x two core 1x four core cable loom not attached RM RL F AI 200 is supplied with additional four core cable loom Black White wires Photocell following contact Volt fr...

Page 3: ...t as standard or telemetry control option Clockwise more sensitive Anticlockwise less sensitive RM RL F AI 50 100 only Orange and brown wires Photocell following contact RM RL F AI 200 only Blue and b...

Page 4: ...t up for optimum image performance Reduces performance May cause hot spots Best performance Camera 1 Adjust vertical position of lamp to ensure full field of view illuminated 2 Tighten all fixings 4 C...

Page 5: ...5 Technical Drawings Not to scale Standard Bracketry Optional Bracketry Wall Mount Dome Mount Ptz Mount Pole Mount RM RL F AI 200 100 50 72mm 2 8 52mm 2 36mm 1 4 8 5mm 0 3...

Page 6: ...max 16W max Input 12 24V DC 24V AC 12 24V DC 24V AC 12 24V DC 24V AC Current 4 0A 12V or 2 0A 24V 2 6A 12V or 1 4A 24V 1 4A 12V or 0 6A 24V Weight 4 0kg 8 8lbs 2 5kg 5 5lbs 1 7kg 3 7lbs Environment I...

Page 7: ...draw of lamp corresponds to specification on page 6 To check lamp current remove ve red lead from external power source and connect multimeter set to 10A in line with the lamp One lead of multimeter...