Raytec RAYMAX DOUBLE FUSION AI Series Installation Manual Download Page 3

3

1x two core, 1x four core cable loom (not attached)

Installation

  

  

Mount illuminator 

Connect Illuminator to low voltage power 
supply: Installers can extend or reduce lead 
length using appropriate cable and weather 
proof box

Input 12-24V DC/ 24V AC

2

3

1

RM/RL F AI 200 only in addition to steps 
4+5 above:

Telemetry input and photocell following 
contact. Remove cap on telemetry and 
photocell following contact connector. 
Connect additional cable loom (see below).

5

7

6

4

Adjust Photocell sensitivity. Remove the cover 
and turn the ‘photocell adjust’ to alter photocell 
sensitivity to ambient lighting condition.

Photocell following contact, volt free relay 
contact - normally open (day) to normally 
closed (night). Photocell following contact as 
standard or telemetry control option.

Clockwise=

more

 sensitive

Anticlockwise=

less

 sensitive

RM/RL F AI 50 & 100 only

Orange 

and

 brown 

wires =

Photocell following contact

RM/RL F AI 200 only

Blue

 and 

black

 wires =

telemetry connection for remote operation

White

 and 

brown

 wires = 

photocell following contact connection

Adjust Power to alter light intensity. 
Remove the cover and turn the ‘power adjust’ 
to alter the intensity of the light level.

Clockwise=

increase

Anticlockwise=

decrease

Note:    Red =

positive

             Black = 

negative

Power 

in

Made in UK

P-cell

adjust

-

+

Power

adjust

-

+

Power

adjust

-

+

Power 

in

Made in UK

P-cell

adjust

-

+

Telemetry P/C 

Contact

Optional Set-up (if required)

Note: Factory set to max. power

RM/RL F AI 50 & 100

RM/RL F AI 200 only

2

1

Note: Replace all covers tightly after 

adjustment to provide IP integrity

Note: Replace all covers tightly after 

adjustment to provide IP integrity

Summary of Contents for RAYMAX DOUBLE FUSION AI Series

Page 1: ...nd point towards scene 2 Adjust vertical and horizontal po sition of lamp to ensure full field of view illuminated 3 Tighten all fixings Package Contents 1 Illuminator including mounting bracket RM RL...

Page 2: ...following contact RM RL F AI 200 1x two core 1x four core cable loom not attached RM RL F AI 200 is supplied with additional four core cable loom Black White wires Photocell following contact Volt fr...

Page 3: ...t as standard or telemetry control option Clockwise more sensitive Anticlockwise less sensitive RM RL F AI 50 100 only Orange and brown wires Photocell following contact RM RL F AI 200 only Blue and b...

Page 4: ...t up for optimum image performance Reduces performance May cause hot spots Best performance Camera 1 Adjust vertical position of lamp to ensure full field of view illuminated 2 Tighten all fixings 4 C...

Page 5: ...5 Technical Drawings Not to scale Standard Bracketry Optional Bracketry Wall Mount Dome Mount Ptz Mount Pole Mount RM RL F AI 200 100 50 72mm 2 8 52mm 2 36mm 1 4 8 5mm 0 3...

Page 6: ...max 16W max Input 12 24V DC 24V AC 12 24V DC 24V AC 12 24V DC 24V AC Current 4 0A 12V or 2 0A 24V 2 6A 12V or 1 4A 24V 1 4A 12V or 0 6A 24V Weight 4 0kg 8 8lbs 2 5kg 5 5lbs 1 7kg 3 7lbs Environment I...

Page 7: ...draw of lamp corresponds to specification on page 6 To check lamp current remove ve red lead from external power source and connect multimeter set to 10A in line with the lamp One lead of multimeter...

Reviews: