7

Trouble Shooting

ensure all tests are undertaken by a qualified, trained engineer. 

ensure safe working practices are followed at all times.

Step 1: Basics

•  Check polarity of Lamp connection

red=+ve, black=-ve

•  Ensure power is 12-24V DC / 24V AC
•  Check photocell is working-cover photocell, light should turn on.
•  Ensure power supply is suitably rated to product - check page 6 for 

specifications

•  If longer cables used, ensure sufficient voltage is provided to allow for drops 

across the cable

If OK…

Step 2: Lamp Test

•  Check current draw of lamp corresponds to specification on page 6 
To  check  lamp  current  remove  +ve  (red)  lead  from  external  power  source  and 

connect multimeter (set to 10A) in line with the lamp. [One lead of multimeter in 

common (COM), other lead into 10A socket of multimeter; set multimeter to read 

Amps]. For correct current settings, see page 6.

Step 3: Set-up Camera, lens and illumination

•  Check alignment of lamp
•  Check camera lens – fully open at night & set correctly
•  Check model number to RayLeD performance specification to ensure 

required distance is achievable

Step 4: Contact RayLeD for further assistance

Note down:
• Model, Angle and Wavelength ve any options
• Serial Number of illuminator
• Camera make and model
• Lens make and model

Summary of Contents for RAYMAX DOUBLE FUSION AI Series

Page 1: ...nd point towards scene 2 Adjust vertical and horizontal po sition of lamp to ensure full field of view illuminated 3 Tighten all fixings Package Contents 1 Illuminator including mounting bracket RM RL...

Page 2: ...following contact RM RL F AI 200 1x two core 1x four core cable loom not attached RM RL F AI 200 is supplied with additional four core cable loom Black White wires Photocell following contact Volt fr...

Page 3: ...t as standard or telemetry control option Clockwise more sensitive Anticlockwise less sensitive RM RL F AI 50 100 only Orange and brown wires Photocell following contact RM RL F AI 200 only Blue and b...

Page 4: ...t up for optimum image performance Reduces performance May cause hot spots Best performance Camera 1 Adjust vertical position of lamp to ensure full field of view illuminated 2 Tighten all fixings 4 C...

Page 5: ...5 Technical Drawings Not to scale Standard Bracketry Optional Bracketry Wall Mount Dome Mount Ptz Mount Pole Mount RM RL F AI 200 100 50 72mm 2 8 52mm 2 36mm 1 4 8 5mm 0 3...

Page 6: ...max 16W max Input 12 24V DC 24V AC 12 24V DC 24V AC 12 24V DC 24V AC Current 4 0A 12V or 2 0A 24V 2 6A 12V or 1 4A 24V 1 4A 12V or 0 6A 24V Weight 4 0kg 8 8lbs 2 5kg 5 5lbs 1 7kg 3 7lbs Environment I...

Page 7: ...draw of lamp corresponds to specification on page 6 To check lamp current remove ve red lead from external power source and connect multimeter set to 10A in line with the lamp One lead of multimeter...

Reviews: