User Manual
101
Total Harmonic Distortion (THD)
< 3 % (of nominal power)
DC current injection
< 0.5 % (of nominal current)
Power factor
> 0.99 at default value at nominal power
(adj. 0.8
Protection
Anti-islanding protection
Yes
AC short circuit protection
Yes
Leakage current protection
Yes
DC fuse (battery)
Yes
DC switch (solar)
Optional
Over-voltage protection
III [Main], II [PV] [Battery]
System Data
Max. efficiency
> 97.7 %
Max. European efficiency
> 97.2 %
Max. charge / discharge efficiency
> 94.0 %
Isolation method (solar)
Transformerless
Isolation method (battery)
HF
Ingress protection (IP) rating
IP65
Pollution degree outside/inside the
enclosure
3 / 2
Operating ambient temperature
range
-25
℃
to 60
℃
(derating when
>
45
℃
)
Allowable relative humidity range
0–100 %
Cooling method
Natural convection
Max. operating altitude
2000 m
Display
Graphic LCD
Communication
2 x RS485, Ethernet, Wi-Fi, CAN
Power management
1 x Digital output
Earth fault alarm
1 x Digital output, email, buzzer inside
Analogue input
PT1000
DC connection type
MC4
AC connection type
Clamping yoke connector
Certification
AS4777, IEC 62109-1, IEC 62109-2, IEC
62477-1, IEC 62040-1, IEC 62116, EN
61000-6-1/-3
Mechanical Data
Dimensions (W x H x D)
457 mm x 515 mm x 170 mm
Mounting method
Wall-mounting bracket
Weight
22 kg