User Manual
10 Operation of LCD Display
51
The contrast value ranges from 0 to 100%. The recommended
value is 50% or 60%.
10.5 Detailed Running Information
On the main screen, there is some basic information about the inverter. For
more detailed running information, please operate as follows.
Main Screen
(
Press
ENTER
)→
Menu
→
Run-info
(
Press
ENTER
)
LCD screen will show four detailed running information pages. Scroll pages by
pressing
/
.
“DC power input” represents the total input power
of PV1 and PV2.
“Vdc” indicates the DC voltage of each input.
“Idc” indicates the DC current of each input.
“Pdc” indicates the DC power of each input.
“Indep / Paral mode” is the PV configuration mode
of the two PV inputs.
√
indicates the corresponding input is at work.
“P-W” is inverter output active power.
“S-Va” is inverter output apparent power.
“Country” is inverter selected country code.
“Grid code” is inverter selected grid code.
“Vac” is phase voltage.
“Iac” is phase current.
“Pac” is AC output of each phase.
“F” is frequency of each phase.
“CO2-reduce” indicates total CO2 emission
reduction due to the inverter.
“E-month” is the energy generation in this month.
“h-Total” is the total running hours of the inverter.
“T-today” is today running time of the inverter.
“Temp” is the internal temperature of the inverter.
This page will appear only when the inverter has a
PV strings current detection function.
10.6 History Records
10.6.1 Running Information Records
Main Screen
(
Press
ENTER
)→
Menu
(
Press
)→
His-record
(
Press
ENTER
)→
Run-record
(
Press
ENTER
)
On the “Run-record”
display, press
to
select the date you
want to view. Confirm
by pressing
ENTER
.