90
Fault name
Explanation
Fault
severity
Measures
Com-Failure
Internal
communication of the
inverter is abnormal
Major
Contact Sungrow.
Encoding
repeat
Addresses of the
interior modules are
repeated.
Major
Contact Sungrow.
Backfeed
Supply fault
Reverse charging
device is out of service.
Major
Contact Sungrow.
IDM-com-flt
The communication of
the tributary board
inside the inverter is
abnormal.
Minor
Contact Sungrow.
DC Sensor-
err
DC sensors of the
inverter are abnormal.
Minor
Contact Sungrow.
Branch fwd-
Idc-high
Branch forward current
is excessively high.
Minor
Contact Sungrow.
Branch rev-
ldc-high
Branch reverse current
is excessively high.
Minor
Contact Sungrow.
T&H-com-flt
The communication of
the temperature &
humidity board is
abnormal.
Minor
Contact Sungrow.
DSP-com-flt
The communication
between control board
and metering board
inside the inverter is
abnormal.
Minor
Contact Sungrow.
11.4 Fault and Troubleshooting on the MV Transformer
Successively tap "Function" -
>
"Run-information"-
>
"Transformer" on the LCD screen to
view the fault information of the MV transformer.
System Manual