73
figure 7-18
Reactive Power Regulation
table 7-9 Reactive Power Regulation
Parameter
Definition/Setting
Description
Range
Reactive power genera-
tion at night
Switch for enabling/disabling
Q at night function.
Enable/Disable
Reactive power ratio at
night
Reactive power ratio set for
the Q at night function.
-100%~0%/
0%~100%
Reactive power setting
persistence
Switch for enabling/disabling
the power-off function during
reactive power.
Enable/Disable
Reactive power regula-
tion mode
—
Off/PF/Qt/Q(P)/Q(U)
Reactive power
regulation
Switch for enabling/disabling
reactive response function.
Enable/Disable
Reactive power regula-
tion time
Ends time of reactive
response.
0.1s~600.0s
Q(P)Curve
Select corresponding curve
according to local regulations
Curve A/Curve B/Curve C*
QP_P1
Output power at P1 on the Q
(P) mode curve (in
percentage)
0.0%~100.0%
QP_P2
Output power at P2 on the Q
(P) mode curve (in
percentage)
20.0%~100.0%
User Manual
Summary of Contents for SG30CX
Page 2: ......
Page 6: ......
Page 10: ......
Page 37: ...27 End User Manual 4 Mechanical Mounting...
Page 113: ...www sungrowpower com Sungrow Power Supply Co Ltd...