User Manual
65
Parameters
SG2K-S
SG2K5-S
SG3K-S
Power factor
> 0.99 at default value at nominal power
(adj. 0.8 leading to 0.8 lagging)
Protection
PV
reverse connection
protection
Yes
AC short circuit protection
Yes
Leakage current protection
Yes
Anti-islanding protection
Yes (frequency shift)
Grid monitoring
Yes
PV string current monitoring
Yes
DC switch
Yes (meet AS60947.3:2018)
AFCI
Yes
Overvoltage category
III [AC], II [DC]
Overvoltage protection
DC Type II / AC Type II
Safety protection class
I
System Data
Max. efficiency
98.2 %
98.2 %
98.2 %
Max. European efficiency
97.2 %
97.5 %
97.7 %
Isolation method
Transformerless
Ingress protection rating
IP65
Power loss in night mode
< 3 W
Pollution degree outside the
enclosure
3
Pollution degree inside the
enclosure
2
Operating ambient
temperature
-25
℃
to +60
℃
Allowable relative humidity
0–100 % (non-condensing)
Cooling method
Natural cooling
Max. operating altitude
4000 m (derating when > 2000 m)
Display
Graphic LCD
Communication
Wi-Fi
PV connection type
MC4 (Max. 6mm
²
)
AC connection type
Plug and play connector (Max. 6mm
²
)
Certification
IEC62109-1, IEC62109-2, IEC62116,
IEC61727, EN 61000-6-2, EN 61000-6-3,
AS/NZS 4777.2
Mechanical Data
Dimensions (W x H x D)
300 mm x 370 mm x 125 mm
Mounting method
Wall-mounting bracket
Weight
8.5 kg
Summary of Contents for SG2K-S