Tab. 4-1
Description of the function of inquiry by push switch (taking 16 lines as an
example)
Item
Description
Voltage and
current
display
Press K1 to turn screen
1
st
current: 10A
2
nd
current: 10A
24
th
current: 10A
Display voltage: 700V
Note: the LED display can be divided into the first two digits and
last three digits. The first two digits is used to display the N
th
input
of the PVS; the last three digits are used to display the current of
this input.
For example: 0110.0 means that the current of the 1
st
input is
10A.
But when the first two digits are 00, the last three digits are the
voltage. For example: 00700 means that the present voltage is
700V.
Communicati
on display
Communication address
A0 007
Baud rate
b9600
Press K2 to turn screen once
Ambient
temperature
display
Ambient temperature
C0 16.8
Press K2 to turn screen twice
Tab. 4-2
Address-setting examples:
Dip-switch settings
Binary
address
Decimal address
0000 0001
1
(
1
×
2
0
=1
)
0000 0010
2
(
1
×
2
1
+0
×
2
0
=2
)
0000 0011
3
(
1
×
2
1
+1
×
2
0
=3
)