48
•
Users in Australia select
Australian Server
.
•
Users in other regions select the
International Server
.
The remote maintenance address will change once the Logger1000 is restart.
step 3 Click
Save
to enter the
Remote Access
interface.
step 4 Enter the login password and click
Confirm
.
step 5 Access information is saved in the following two ways.
•
Click
Copy remote access information
, and save the access information locally after
successful copying.
•
Enter the email address and click
Send
to send the access information to the email
address.
step 6 Enter the access link in the URL field to enter the
Remote Maintenance
interface. Enter the
device S/N and password, and click
Login
to perform remote maintenance.
- - End
7.10.4 Message Export
step 1 Click
System→Message Export
to enter the corresponding interface.
table 7-4 Parameter description
Parameter
Description
Range
Port
-
Serial port: COM1
、
COM2
、
COM3
Network port: ETH, WiFi, 4G
Duration
Export the message
recorded during the set time
1min ~ 10min
step 2 Set parameters, including
Interface
,
Serial Port
, and
Duration
, and click
Start
to start
recording message. The recording automatically stops when the set time reaches, or the
user may manually click the button
Stop
to stop recoding message.
step 3 Click
Export
to export the message.