toggled in before delivery, if need to change the input voltage, please

toggle the switch cap into correct position before power on .

7.1.2. Motor interface:

The 24V DC brushless/servo motor has 8 wires connected to control board.

7.1.3. Power interface:

Power supplies output 24/12V DC to control board, one is supply power to

motor, one is supply power to control unit.

7.1.4. R&G (LED) light power supply:

There is power supply specially for R&G light, if you connect to 24V or

12V power supply, the R&G light input should be consistent.

7.1.5. R&G light interface:

When

boom

falling

down

to horizontal position, red light will

keep lighting; when boom lifting up to vertical position, green light will

keep lighting. During the boom falling down or lifting up, the red light will

keep lighting. (Please refer to

Appendix

III for wire diagram)

The interface also can be used to output open limit signal and close limit

signal, Please check wiring Figure 4 for reference(Optional output).

7.1.6. Wire control signal input interface:

This interface is dry contact input signal, UP/ DOWN / STOP connect

with “COM ”, the control board will respond accordingly. User can use

this interface to connect with parking system, and it can

also wiring connected to button switch to control the barrier. (Please refer

to

Figure 4 f

or for main control board wire control)

7.1.7. Photocells interface:

This interface is dry contact input signal, only for responding opening

when shorts circuit the terminal “Photocells” during closing. This is

mostly use for prevent damage when boom falling. So normally

photocells are installed paralleled and under the arm. Boom will keep

open, or will auto-reverse when there are obstacles between photocells.

7.1.8. Loop detector interface:

This interface is dry contact input signal, only for responding to auto

closing after signal input and then disappeared. So first it

should received dry contact or relay input, after the input

signal disappeared, boom will auto falling to closed

7.1.9. RS485 interface:

This interface is used for communication between computer and

SFMCU control unit. We provide SDK for customers to develop

software to receive barrier gate status and control barrier gate

operations.

7.1.10. Battery interface:

This interface is used for battery, the battery can be used to keep

barrier gate working normal when power off.

7.1.11. Other interface(Arm detection):

Currently it’s used for arm detection. This function is not open

unless needed, you can open this function from menu settings.

Please see

Appendix VI

for reference.

7.1.12. SET button:

3 buttons for menu setting, INC, SET, DEC, setting guidance please refer

to Appendix V

7.1.13. Manual control button

‘UP’, ‘DOWN’, ‘STOP’ , these 3 buttons allow you to control barrier

gate open, close and stop by manual. The stop button also used as save

setting button.

7.2. Controller auto-detect after power-on description.

When the arm is in open position, the controller should re-confirm the close

position of boom after power-on or resume power: The barrier gate will

auto close slowly one time by default. This require the boom are installed,

if not controller can not close to right position. During the re-confirming

process, it detects all open and anti-bumping signal interface, and it will

stop learning if there is signal. After finish leaning, the boom stays at the

down limit position and Buzzer will beep one time.
If spring installed but no boom, or there is obstacles on the boom during

down process, or the spring and boom in serious imbalance, need to

remove the obstruction or adjust the spring, then power-on again.

If boom is in closing position when, please do not hold or stop the arm

move, the barrier gate will confirm it’s close position very soon.

8. Boom horizontal and vertical fine adjustment

8.1 Horizontal adjustment:

Power off first. And loosen the two

screws(see figure 5) on balance

rotating arm a little but not totally

loosed, then rotate barrier arm to

make the active swing arm to

mechanical limit position. In this

situation, keep the arm in

horizontal status, and fasten the

Figure 5

Summary of Contents for S10

Page 1: ...Operating Instructions DC Servo Barrier Gate S10 SFMCU MicroDrive V1 0 ...

Page 2: ... Introduction SUNFRE S10 DC Brushless Servo motorized barrier gate the newly designed maintenance free with exclusive SFMCU MicroDrive unit offers 100 more torque 100 duty are the fastest toll barriers available with an opening time as fast as 0 6 seconds Opening speed is adjustable from 0 6s 0 9s to 6s or more This barrier redefines performance in non stop toll applications It is the ideal soluti...

Page 3: ...cess Reader or Push button or remote controller can be used to trigger the barrier gate to open via a simply dry contact signal After delay timer elapsed barrier gate will close automatically by itself in a certain time optional function 3 8 USER FRIENDLY Motorized arms provide comfortable passage while maintaining a high level and high density of car flow management such as in toll gate 3 10 AUTO...

Page 4: ...nscrew the fastening wing nuts in the bottom of the spring by manual then take off the spring The steps for installation and dis assembly the spring are the opposite 6 2 3 Spring force adjustment When power off adjust the springs balance to make sure the arm will stay in the angle 45 60 degrees towards the horizontal and not going down or going up which mean the spring force is well balanced 7 Cont...

Page 5: ...signal disappeared boom will auto falling to closed 7 1 9 RS485 interface This interface is used for communication between computer and SFMCU control unit We provide SDK for customers to develop software to receive barrier gate status and control barrier gate operations 7 1 10 Battery interface This interface is used for battery the battery can be used to keep barrier gate working normal when powe...

Page 6: ...below items and situations are not included in the range of free service 10 4 1 The user does not follow the instruction and cause any damage of the product 10 4 2 The power supply is not stable over the range of permitted voltage or not accordant to safety electric using standard 10 4 3 The user installs or uses the product in wrong methods cause damage to the appearance of product 10 4 4 Natural...

Page 7: ...ttom port is state 0 Empty is state X The code as below is 10XX0X1X Warning please take out the battery before coding Appendix III Wiring Diagram for R G Light Interface Appendix IV Wiring Diagram for up and down limit output No need Power Boom Length Meter M Spring Diameter Φ mm Suggested max speed Straight Boom Link Hole Selection 2 L 2 5 empty 3 5 0 6 4 L 3 empty 4 5 0 9 4 5 L 4 3 5 4 5 1 2 6 L...

Page 8: ...the speed controlled vice verse Default value is 5 DP07 Max braking strength when closing 0 10 The strength of braking when closing DP08 Default DP10 Opening angle 0 100 Horizontal degree is 0 when power on barrier gate will auto close to find 0position open to position degree is about 90 degrees Sometimes the degrees will more than or less than because of mechanical parts matching or precision is...

Page 9: ...CHAS CHACK SENSOR Sensor check E PL ERROR PULSE Motor Default Phase E CS Gate operation overtime RUNX X is the system operation Mode and the Setting Value of LP02 System Normally Operating dPXX Menu Driven Display NPXX no User Menu Display P H Dates resuming to be Default Value P F Dates resuming Default Value NOPR NO POWER Opening when no power TEST Gate self testing INXX IN NUM xxthe entering ve...

Reviews: