background image

My booth won’t work with the T-Max® Manager remote system

1. 

The booth must first be set to a unique address, see Remote 

Connections.

2. 

The bypass plug may be installed in the series in an inap-

propriate location. Remove bypass plugs when using TMax® 
products.

When auto-addressing the first bed does not register an address

When using the auto address feature of the T-Max® Manager 
you must wait 10 seconds from the time you start the auto ad-

dress function before addressing the first bed.

I forgot what address I set my booth to

By pressing the stop button and then the timer button, and 
holding both for 3 seconds, the timer display will show the 
booth’s address number. Press the stop button to exit address 
mode.

My both is connected to the T-Max® Manager remote system and 
when the delay time has expired the timer display starts counting 
down but the booth lights do not come on

The auto start feature of the remote system is disabled, see the 
instructions provided with your remote system.

My booth, connected to a T-Max® Manager, did not display “dL” but 
does indicate:
 “0”

1. 

Remote device has not been set.

2. 

The booth has not been connected to the remote system, 

see Remote Connections.

 

a tanning time and the lamps have come on

1. 

Delay time of T-Max® Manager has not been set.

2. 

Delay time has expired and session has begun.

 

a tanning time but the lamps have not come on

Auto start function of T-Max® Manager has been turned off. 
Press the timer button to turn on lamps.

Booth not tanning

1. 

Clean booth, see Thorough Periodic Cleaning.

2. 

Ensure supply voltage is between 208 and 230V AC.

3. 

Replace lamps if lamp hours are greater than 700hrs.

4. 

Replace acrylic.

Lamps fail to light and timer display is blank

1. 

Make sure the unit is connected to a power source.

2. 

Check source of AC power. Reset circuit breaker or replace 

fuse.

Timer display changes to indicate a tanning time after the timer button 
is pressed but lamps do not come on

1. 

Bypass plug is not installed, see Electrical Connections.

2. 

A bypass plug other than the one sent with your tanning 

booth has been used.

3. 

If remote is being used, other than T-Max® Manager, the 

external timer may not be activated.

4. 

Remote wiring is incorrect, see the instructions provided 

with the remote interface kit.

Timer display continues to show a 0 after the timer button is pressed

1. 

T-Max® Manager remote system has not yet been set.

2. 

Booth address is not set correctly, see Remote Connections.

One or more lamps fail to light

1. 

Check that lamp is installed correctly.

2. 

Switch unlit lamp with a lamp that lights, if new lamp lights 

and old lamp still does not, replace old lamp.

Problem

  

Troubleshooting

 

Solution

Problem

  

Troubleshooting

 

Solution

7

Replacing Lamps

To be assured of maximum tanning effectiveness, change lamps after 
approximately 500 hours of use. Tanning will continue after this time 

but at a slower rate. We recommend using the lamps specified below. 
Use of uncertified lamps is a violation of Federal regulations and may 

void your warranty.

Grasp a lamp at one end and at the middle, then turn the lamp a 

quarter turn. The lamp may then be gently removed from its holder.

To reinstall lamp, insert pins on the ends of the lamp into the slots on 

top of the lamp holder and turn the lamp a quarter turn.

The following lamps have been certified for use in this equipment:

Sunfire® Plus

 FR71/160W

Hour Counter

This booth incorporates an ingenious hour counter function into the 
timing circuitry. It allows the operator of the unit to monitor the hours 
of use of the lamps, making it easy to determine when to change them. 
You may also decide to use this function to monitor other time based 
maintenance tasks.
To determine how many hours the unit has been in service (since the 

last reset of the hour counter memory), first make sure the timer display 

shows “0”. Then simply hold the stop button for three seconds.
The display will show two pairs of numbers which indicate the number 
of hours of service, then return to “0”. (example: Display shows 08 then 

54. This equals 854 hours.) NOTE: If the unit is connected to a TMax® 
remote device, it may briefly lose communication with the remote. This 

is normal.
To erase the indicated hours, disconnect power from the booth. Press 
and hold the green timer button as you reconnect power. Release the 
button after a few seconds.

Summary of Contents for Platinum PRO48X

Page 1: ...Make sure nothing obstructs the airflow into the booth s endcaps or out of the fan openings A poorly ventilated room may cause the unit to become hot and cause discomfort to the user Unpacking and Inspection Your booth arrives in three cardboard cartons Pull back the plastic sheet and with a helper grasp each unit and pull it from the carton bottom leaving the plastic wrap and the carton packaging...

Page 2: ...WHEELS Connect the Door Unit to the Control Unit As before be sure the white Nylon Washer is between the hinge brackets 3 The Side Brace keeps the Control Unit and Side Unit from opening up Position the two units as shown and insert the pins on the Side Brace into the holes in the extrud ed bosses on the endcaps Move the units until the brace fits into the holes 2 Secure the body fan bracket to th...

Page 3: ...t prématuré de la peau et provoquer le cancer de la peau PORTEZ DES LUNETTES PROTECTRICES LE NON RESPECT DE CETTE CONSIGNE DE SÉCURITÉ PEUT ENTRAÎNER DE GRAVES BRÛLURES OU DES LÉSIONS OCULAIRES À LONG TERME Les médicaments ou les produits cosmétiques peuvent augmenter votre sensi bilité au rayonnement ultraviolet Consultez un médecin avant d utiliser la lampe solaire si vous prenez des médicaments...

Page 4: ...vide the needed power to the wireless unit Remote System Hook up Scenarios Follow the diagrams below and on the next page to see the many differ ent scenarios for hooking up your salon If you need further assistance call T Max directly at 417 272 0761 Scenario 1 T Max Manager Series with Complete Wireless Connect one G2 with Power Injector to the Manager and one G2 to each of the tanning units Ins...

Page 5: ...display should indicate an address number from 1 to 255 3 If you are using a T Max 1A or 3A as a master remote the ad dress of the booth must be set to 1 If you are using a TMax Man ager each sunbed must be assigned a different address To adjust the address press the green timer button to count up until the desired number from 1 to 128 is achieved Addresses 252 to 255 are not normally used 4 Press...

Page 6: ...es of the acrylic shield are now exposed Grasp the edge of the acrylic and carefully lift it out Replace the acrylic by placing it back into place Close the hinged profile by pushing it back into place until it snaps tight CAUTION Be careful The edges of the acrylic shield may be sharp PROFILE ACRYLIC 6 Operation A Timer display Displays remaining time B Timer button Turns booth on Timer display s...

Page 7: ...th has been used 3 If remote is being used other than T Max Manager the external timer may not be activated 4 Remote wiring is incorrect see the instructions provided with the remote interface kit Timer display continues to show a 0 after the timer button is pressed 1 T Max Manager remote system has not yet been set 2 Booth address is not set correctly see Remote Connections One or more lamps fail...

Page 8: ... changes or improve ments in its products without incurring any obligations to similarly alter products which have been previously purchased 8 Exclusivity of Warranty This warranty is the only warranty made by SUNFIRE INDUS TRIES and may only be modified or amended by a written instrument signed by a duly authorized officer of SUNFIRE INDUSTRIES SUNFIRE INDUSTRIES s sole and exclusive liability an...