52
SUNFAR E300 SERIES
Data return: data correct set.
Slave
return
Header
Slave
addr.
Slave
correspond
State
feedback
Data type
Data
addr.
Set data
Check
sum
Tail
Digit 1 2
1
2
1
2 4
4 1
2A
30 30
30
30 33
30
30 31
30 31
46 34
30 32
35 46
0D
E.g.
5A
00 00
00
00 03
00
00 01
00 00
01 F4
00 00
00 F9
0D
Explain Header
0 slave
return
Slave receive
data
Slave stop
state
F0
Parameter
unit
F0.1
Set data
50.0HZ
Adding
hex
Tail
1.4.5 Send control order (order type 4)
Data return: set slave 0 inverter FWD running freq 10.0 Hz.
Master send Header Slave addr. Order type Operation order
Set data
Check sum Tail
Digit 1 2
1
2
4
4 1
2A
30 30
34
31 31
30 30
36 34
30 31
43 30
0D
E.g.
5A
00 00
04
00 11
00 00
00 64
00 00
00 79
0D
Explain Header Addr. 00
4 order FWD with freq set Set freq 10.0 Hz Adding hex Tail
Data return: 0 inverter receives data normally.
Slave
return
Header
Slave
addr.
Slave
correspond
State
feedback
0
Monitor
item
Running data
Check
sum
Tail
Digit 1 2
1
2 1 2
4
4 1
2A
30 30
30
30 31
30
30 30
30 30
36 34
30 32
34 42
0D
E.g.
5A
00 00
00
00 01
00
00 00
00 00
00 64
00 00
00 65
0D
Explain Header
0
slave
return
Slave
receive
data
Slave
FWD
running
Fixed
data
Present
display
monitor
d-0
Data set
successfully
Adding
hex
Tail
E300 Series Mini-type Integrated Universal Inverter Manual