![Sunfar E300 Series Manual Download Page 58](http://html1.mh-extra.com/html/sunfar/e300-series/e300-series_manual_1396022058.webp)
SUNFAR E300 SERIES 51
1.4.3 Read function code parameter (order type 2)
Data set: read parameter [F0.8]
Master
send
Header
Slave
addr.
Order
type
Operation order
Data type
Data addr.
Check
sum
Tail
Digit 1 2 1
2
1
2
4 1
2A
30 30
32
30 30
30
30 38
30 31
38 41
0D
E.g.
5A
00 00
02
00 00
00
00 08
00 00
00 0A
0D
Explain Header Addr. 00 2 order
Invalid control
order
F parameter
unit
F
parameter
Adding
hex
Tail
Data return: carrier wave freq [F0.8]
=
8.0KHz.
Slave
return
Header
Slave
addr.
Slave
correspond
State
feedback
Data type
Data
type
Return data
Check
sum
Tail
Digit 1 2
1
2
1 2
4
4 1
2A
30 30
30
30 33
30
30 38
30 30
35 30
30 32
35 30
0D
E.g.
5A
00 00
00
00 03
00
00 08
00 00
00 50
00 00
00 5B
0D
Explain Header
0 slave
return
Slave
receive data
Slave stop
state
F0
Parameter
unit
F0.8
Return data
as 8.0KHz
Adding
hex
Tail
1.4.4 Modify RAM area function code parameter (order type 3)
Data set: modify data set freq [F0.1]=50.0Hz, not keep when stop.
Master
send
Header
Slave
addr.
Order
type
Operation
order
Data type Data type Set data
Check
sum
Tail
Digit 1 2 1
2
1
2
4
4 1
2A
30 30
33
30 30
30
30 31
30 31
46 34
30 32
35 46
0D
E.g.
5A
00 00
03
00 00
00
00 01
00 00
01 F4
00 00
00 F9
0D
Explain Header
Addr.
00
3 order
Invalid
control order
F0
Parameter
unit
F0. 1
Parameter
Set freq
50.0Hz
Adding
hex
Tail
E300 Series Mini-type Integrated Universal Inverter Manual