18
SUNFAR E300 SERIES
F1.17
Overload warning
delay time
0.0 ~ 20.0 S
0.1
2.0
×
F2.0
Startup freq
0.0 ~ 50.0 Hz
0.1
1.0
F2.1
Startup freq lasting
time
0.0 ~ 20.0 S
0.1
0.0
×
F2.2
Stop mode
0: Dec stop 1: Free stop
1
0
F2.3
DC braking initial
freq when stop
0.0 ~ 500.0 Hz
0.1
3.0
F2.4
DC braking action
time when stop
0.0 ~ 20.0 S
0.1
0.0
×
F2.5
DC braking action
volt when stop
0 ~ 50 (%)
1
10
F2.6
FWD jog freq
0.0 Hz~ upper freq
0.1
10.0
F2.7
REV jog freq
0.0 Hz ~ upper freq
0.1
10.0
F2.8
Acc moment level
110 ~ 200 (%)
1
170
F2.9
Motor overload
protection coefficient
50 ~ 110 (%)
1
100
Aux
iliar
y r
un
ni
ng par
am
eter
uni
t
F2.10
Initial volt of dynamic
braking (E300B
series)
300 ~400V
600 ~ 800V
1
370
740
F3.0
Multi-speed freq 1
0.0 Hz ~ upper freq
0.1
35.0
F3.1
Multi-speed freq 2
0.0 Hz ~ upper freq
0.1
15.0
F3. 2
Multi-speed freq 3
0.0 Hz ~ upper freq
0.1
3.0
F3. 3
Multi-speed freq 4
0.0 Hz ~ upper freq
0.1
20.0
F3. 4
Multi-speed freq 5
0.0 Hz ~ upper freq
0.1
25.0
F3. 5
Multi-speed freq 6
0.0 Hz ~ upper freq
0.1
30.0
F3. 6
Multi-speed freq 7
0.0 Hz ~ upper freq
0.1
35.0
F3. 7
Linear speed
coefficient setting
0.01 ~ 10.00
0.01
1.00
F3. 8
Monitor parameter
selection
0 ~ 21
1
0
F3. 9
Parameter check
and modification
authority
0 ~ 9999
1
1700
Mult
i-s
pee
d a
nd s
en
ior
r
u
n
nin
g p
ar
a
met
er
un
it
F3. 10
Parameter
initialization
0: No action
1: Standard initialization
2: Eliminate failure record
3: Complete initialization
1 0 ×
E300 Series Mini-type Integrated Universal Inverter Manual