Bi-spectrum network camera
User Manual
Intelligent Analysis
Issue V 1.1
(
2022-05-07
)
81
Table 6-3
Description of Parameters for Personnel Count
Parameter
Description
Setting
Channel
Channel 1: visible.
Channel 2: thermal.
[How to set]
Choose one channel to
set.
Enable
Enable the button to enable the alarm.
[How to set]
Click Enable to enable.
[Default value]
OFF
OSD Enable
Enable the OSD, the count data will show
on live video screen.
[How to set]
Click Enable to enable.
[Default value]
OFF
Counting Clear
Interval
The camera will clear counting data at
the setting interval.
Click the
“
Clear Counting
”
, clearing the
data immediately.
[How to set]
Choose from drop-
down list.
[Default value]
12 hours
Area Type
Draw a line on live video screen.
The label of A and B indicate out and in.
[How to set]
Choose from drop-
down list.
[Default value]
Line
Set Correction
Value
Enable, set the count correction value, it
can be positive or negative. For example,
if there are 30 people enter the area
before counting, input 30 to correct. If 30
people go out the area, input -30.
[How to set]
Enable /Input a value
in the area box.
[Default value]
0
Over People
Number Alarm
Enable, if the counting number is passing
the threshold, it will alarm.
[How to set]
Click Enable to enable.
[Default value]
OFF
Alarm Threshold
the threshold of enable alarm.
[How to set]
Enable /Input a value
in the area box.
[Default value]
1000