background image

 

6

 

8. VENTILATION SYSTEM 

This microwave is designed for adaptation to three types of hood ventilation systems. Select the type 
required for your installation. 

A.

 

Recirculating non-vented, ductless. Follow installation procedure A. 

a.

 

Recirculating requires the use of the Charcoal Filter 11. 

b.

 

This is packed under the microwave in the carton. 

B.

 

Horizontal Exhaust outside ventilation. Follow installation procedure B. 

C.

 

Vertical Exhaust outside ventilation. Follow installation procedure C. 

 
 
 
 
 
 
 
 
 
 

 

(A)

 

RECIRCULATING: Non-vented, Ductless Operation 

The unit is shipped assembled for recirculating. Attach the Charcoal Filter to the upper side of the 

microwave by sliding into the tabs. See Figure 9.   

NOTE: 

1.

 

The Exhaust Damper Assembly 11 is not required for recirculating operation. 

2.

 

The Charcoal Filter should be replaced every 6 to 12 months, depending on use. 

3.

 

The Charcoal Filter is also sold as an accessory. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

f i g. 7

 

 

f i g. 8

Fig. 9 

Fig. 10 

Summary of Contents for SNM1501RAB

Page 1: ...Installation Instructions Over the Range Microwaves Models SNM1501RAW SNM1501RAB SNM1501RAQ SNM1502RAS PTT072506...

Page 2: ...If the wall is not flat use spacers to fill in the gaps Wall construction should be a minimum of 2 4 wood studding and 3 8 or thicker dry wall or plaster lath The mounting surfaces must be capable of...

Page 3: ...es 4 HOOD EXHAUST DUCT When the hood is vented to the outside a hood exhaust duct is required All ductwork must be a metal absolutely do not use plastic duct Check that all connections are made secure...

Page 4: ...also use carton for protection Scissors Pencil Tape Measure Tape 6 INSTALLATION HARDWARE The INSTALLATION HARDWARE items are in a small carton packed below the microwave ITEM NAME QUANTITY 1 Inflatin...

Page 5: ...bent or loose door hinges and latches and dents inside the cavity or on the door If there is any damage do not operate the microwave and contact your dealer Remove and save Screw A as shown in Figure...

Page 6: ...tside ventilation Follow installation procedure B C Vertical Exhaust outside ventilation Follow installation procedure C A RECIRCULATING Non vented Ductless Operation The unit is shipped assembled for...

Page 7: ...e back of the Mounting Plate by sliding it into the slits in the same direction as the arrow See Figure 12 Using Tapping screw 4 12 from the INSTALLATION HARDWARE tighten into place C VERTICAL EXHAUST...

Page 8: ...ept i n t he m i ddl e t he t op shoul d be 1 8mf rom ground 0 9mf rom cooki ng area not e i f t he f ront l ow er t han t he back edge m ake t he t op edge paral l el w i t h f ront edge of t he cabi...

Page 9: ...om or in the US call 1 866 866 6283 2006 Sunbeam Products Inc doing business as Jarden Consumer Solutions All rights reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under licen...