5. Install the L brackets on the outer sill with the 
short side of the bracket against the back of the 
inner sill.  Install one L bracket 7.5

 to each side

of center line. See Fig. 5.

Fig. 5

Center Line

Short Side

Bracket

Inner Sill

Outer Sill

7.5

7.5

6. Carefully lift the air conditioner and slide it into
the open window.  Make sure the bottom guide of 
the air conditioner drops into the notches of the L
brackets.  When the air conditioner drops into the L 
brackets, the air conditioner will be centered in window 
opening as show in Fig. 6. 
While steadying the air conditioner, carefully bring
the window sash down behind the top channel 
of the air conditioner, as shown in Fig. 7. 
First, fix both sides onto the window sill with two 3/4
screws and one 2/5

screw ( which is unscrewed from

each side of the unit).  Then fix top channel to widow
sash with one 3/4

screw and fix side curtain frames 

with four 3/4

screws as shown in Fig.6.  

Fig. 6

Fig.7

About 5

L Bracket

Seal 

7. If storm window  presents interference, fasten a 
2'' wide wood strip to the inner window sill across
the full width of the sill.  The wood strip should be thick
enough to raise the height of the window sill so that 
the unit can be installed without interference from the 
storm window frame, as show in Fig. 8.
Top of wood strip should be approximately 3/4''  higher 
than the storm window frame to help condensation to

 

drain properly to the outside.
Install a second wood strip (approximately 6'' long by 
1

1/2

''wide and same thickness as first strip) in the center 

of the outer sill flush against the back of the inner sill.
Screw the L brackets into this strip.
This will raise the L bracket as shown in Fig. 8.

Fig.8

3/4''Clearance

Storm window 
frame

Inner sill

Foam

3/4''  Screw

3/4''  Screw

Mode

Timer

  Fan

Airconditioner

3/4

screw

3/4

screw

2/5

screw

3/4

screw

3/4

screw

3/4

screw

3/4

screw

3/4

screw

Summary of Contents for SCA062RWB1

Page 1: ...User s Manual 5 850 BTU Room Air Conditioner Model SCA062RWB1 20060316...

Page 2: ...ontents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide 1 Page 2 2 4 5...

Page 3: ...tructions completely before starting This manual contains information for the installation and operation of your room air conditioner Cabinet Exterior Air Inlet Interior Air Outlet Control Knob Note T...

Page 4: ...onsequently the shape may differ from that of the air conditioner you have selected Power Cord Front Panel Horizontal Air Vane Vertical Air Vane Fresh Air Lever for 8K model only Interior Air Inlet Gr...

Page 5: ...ing plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit If the air conditioner has a serial plate rating of 115 volts and up to and...

Page 6: ...utdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting 2 5 Screws 8...

Page 7: ...For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over t...

Page 8: ...the guides of the air conditioner Fasten the curtains to the unit with screws Fig 2 Fig 3 3 Cut the adhesive backed seal strip the window width Remove the backing from the seal strip and attach the se...

Page 9: ...ix top channel to widow sash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 Fig 6 Fig 7 About 5 L Bracket Seal 7 If storm window presents interference fasten a 2...

Page 10: ...tomatically with minimum air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW...

Page 11: ...fan speed Cooling Fan only Display set temp Display set timer Timer Energy saving Indication symbols of LED on control panel Fan Speed button Used to select fan speed in sequence auto low medium and...

Page 12: ...ol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the mid same as low mode fan speed 6 Low BUTTON Used to select the low mode fan speed 7 Auto BUTTON Used to select t...

Page 13: ...rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim 12 To operate the room air conditioner aim the remote control to the signal receptor The remote co...

Page 14: ...sp the filter handle tab located on the up center side of the air inlet grille and slide the air filter to the up To reinstall the air filter reverse the above procedure DO NOT forget to install the a...

Page 15: ...tside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot...

Page 16: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: