Sunbeam SCA062RWB1 User Manual Download Page 5

1. All wiring must comply with local and national
electrical codes and must be installed by a 
licensed electrician.  Once you have any 
questions regarding the following instructions, 
contact a licensed electrician.

2. Check available power supply and resolve any
wiring problems 

BEFORE

 installing and operating 

this unit.

3. For your safety and protection,  this unit is
grounded through the power cord  when
plugged into a matching wall outlet.  

If you are

not sure whether your wall outlet is properly
grounded, please consult a licensed
electrician

.

4. The wall outlet(3-pin) must match the plug
(3-pin) on the power  cord supplied with the unit.
DO NOT use plug adapters or extension cords.

See (Table 1)

 for receptacle and fuse information. 

5. The rating plate on the unit contains electrical 
and other technical data.  The rating plate is located 
on the right side of the unit.

If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps
the unit maybe on a fuse or circuit breaker
with other devices.  However, the maximum 
amps of all devices on that fuse or circuit 
breaker can not exceed the amps of the fuse
of circuit breaker.

If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it 
must have its own fuse or circuit breaker, 
and no other device or unit should be 
operated on the fuse or circuit breaker.

To avoid the possibility of personal injury, 
disconnect the  power to the unit before 
installing or servicing.

Electric Shock Hazard

Electrical specifications

125

5K

6K

8K

Table 1

15

15

RATED VOLTS

COOLING CAPACITY

AMPS

FUSE SIZE

WALL OUTLET

             RECEPTACLE AND FUSE TYPES

!

Time Delay Fuse 
(or circuit breaker)

Plug type

Summary of Contents for SCA062RWB1

Page 1: ...User s Manual 5 850 BTU Room Air Conditioner Model SCA062RWB1 20060316...

Page 2: ...ontents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide 1 Page 2 2 4 5...

Page 3: ...tructions completely before starting This manual contains information for the installation and operation of your room air conditioner Cabinet Exterior Air Inlet Interior Air Outlet Control Knob Note T...

Page 4: ...onsequently the shape may differ from that of the air conditioner you have selected Power Cord Front Panel Horizontal Air Vane Vertical Air Vane Fresh Air Lever for 8K model only Interior Air Inlet Gr...

Page 5: ...ing plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit If the air conditioner has a serial plate rating of 115 volts and up to and...

Page 6: ...utdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting 2 5 Screws 8...

Page 7: ...For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over t...

Page 8: ...the guides of the air conditioner Fasten the curtains to the unit with screws Fig 2 Fig 3 3 Cut the adhesive backed seal strip the window width Remove the backing from the seal strip and attach the se...

Page 9: ...ix top channel to widow sash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 Fig 6 Fig 7 About 5 L Bracket Seal 7 If storm window presents interference fasten a 2...

Page 10: ...tomatically with minimum air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW...

Page 11: ...fan speed Cooling Fan only Display set temp Display set timer Timer Energy saving Indication symbols of LED on control panel Fan Speed button Used to select fan speed in sequence auto low medium and...

Page 12: ...ol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the mid same as low mode fan speed 6 Low BUTTON Used to select the low mode fan speed 7 Auto BUTTON Used to select t...

Page 13: ...rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim 12 To operate the room air conditioner aim the remote control to the signal receptor The remote co...

Page 14: ...sp the filter handle tab located on the up center side of the air inlet grille and slide the air filter to the up To reinstall the air filter reverse the above procedure DO NOT forget to install the a...

Page 15: ...tside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot...

Page 16: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: