Operating Instructions

 10

Mode button

Each time  Mode button is pressed, the operation
mode is changed in sequence:
5K

6K

8K cooling only

COOLING

FAN ONLY

ENERGY SAVING 

COOLING

8K with heater 

COOLING

FAN ONLY

HEATING

ENERGY SAVING

COOLING

 

NOTE:

 After setting the mode, allow 3 minutes before switching

 to another mode. 

Room Temperature below 32

,the Temperature display L0.

Room Temperature above 99

,the Temperature display H1.

          Button

The air conditioner will be started when it is energized or will
be stopped when it is in operation, if you press this button.
When the air conditioner is heating, allow  3 minutes after you 
press this button.

Control Panel

You can easily operate this air conditioner by pressing  relevant 
button  on the control panel as well as the remote control.

 Above LED lights on when the relevant mode is in used. 

 

Control Panel

Mode

Timer

Airconditioner

F

  
h

High fan speed

Medium fan speed 

Low fan speed

Auto fan speed

Cooling

Fan only

Display set temp
Display set timer

Timer

Energy-saving

Indication symbols of LED on control panel :

Fan Speed  button

Used to select fan speed in sequence auto, low, medium 
and high (low and medium are in same fan speed).

 

Timer  button

Used to set or cancel timer operation.

When the unit is in operation, you can set OFF TIMER.
When the unit is off, you can set ON TIMER.
Timer setting range is 0 to 24 hours.

If  the OFF TIMER is set,  the  timer  LED  displays  the

 remaining  time  to turn off the unit for only 12 seconds,
 then LED shifts to display set temperature. If you press 

TIMER button within the 12 seconds, OFF TIMER will be
canceled.

If  the ON  TIMER is  set,  the  timer LED  displays  the
remaining time to turn on the unit. If you want to cancel

 ON TIMER, press TIMER button.  

 Button

NOTE:

 Temperature setting range is from 19

(66

) to 31

(88

).

 

Used to set room temperature in COOLING mode or used to set time in TIMER mode.
If the two keys are pressed at the same time, the temperature LED display will  alternate  between

 and 

.

  

  Fan
Speed

Heating

In the FAN ONLY Mode , Room Temperature display  range is 
from 0

(32

) to 38

(99

).

Summary of Contents for SCA062RWB1

Page 1: ...User s Manual 5 850 BTU Room Air Conditioner Model SCA062RWB1 20060316...

Page 2: ...ontents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide 1 Page 2 2 4 5...

Page 3: ...tructions completely before starting This manual contains information for the installation and operation of your room air conditioner Cabinet Exterior Air Inlet Interior Air Outlet Control Knob Note T...

Page 4: ...onsequently the shape may differ from that of the air conditioner you have selected Power Cord Front Panel Horizontal Air Vane Vertical Air Vane Fresh Air Lever for 8K model only Interior Air Inlet Gr...

Page 5: ...ing plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit If the air conditioner has a serial plate rating of 115 volts and up to and...

Page 6: ...utdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting 2 5 Screws 8...

Page 7: ...For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over t...

Page 8: ...the guides of the air conditioner Fasten the curtains to the unit with screws Fig 2 Fig 3 3 Cut the adhesive backed seal strip the window width Remove the backing from the seal strip and attach the se...

Page 9: ...ix top channel to widow sash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 Fig 6 Fig 7 About 5 L Bracket Seal 7 If storm window presents interference fasten a 2...

Page 10: ...tomatically with minimum air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW...

Page 11: ...fan speed Cooling Fan only Display set temp Display set timer Timer Energy saving Indication symbols of LED on control panel Fan Speed button Used to select fan speed in sequence auto low medium and...

Page 12: ...ol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the mid same as low mode fan speed 6 Low BUTTON Used to select the low mode fan speed 7 Auto BUTTON Used to select t...

Page 13: ...rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim 12 To operate the room air conditioner aim the remote control to the signal receptor The remote co...

Page 14: ...sp the filter handle tab located on the up center side of the air inlet grille and slide the air filter to the up To reinstall the air filter reverse the above procedure DO NOT forget to install the a...

Page 15: ...tside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot...

Page 16: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: