Thermostat knob

Mode knob

When using FAN control, turn slowly allowing unit
to adjust.

When using 

THERMOSTAT

, be sure to allow three

minutes before changing temperature. Adjusting
too quickly may cause an overload resulting in a
blown fuse.

CAUTION

!

!

MODE

Fig.9

The mode knob controls fan speeds and cooling
speeds. To set desired cooling temperature, simply
rotate the mode knob dial to the appropriate
setting. See Fig. 9.

LOW FAN

 will circulate the air at a minimum speed

without cooling.

HIGH FAN

 will circulate the air at a maximum speed

without cooling.

LOW COOL

 provides cooling, automatically with

minimum air circulation. Recommended for night-
time use.

HIGH COOL

 provides cooling, automatically with

quick cooling or for extremely hot days. Once room 
is cooled, reduce setting to

 LOW COOL

.

NOTE:

 After setting the mode, allow 3 

minutes before switching to another mode. 

OFF 

will completely shut-off the unit.

THERMOSTAT

The thermostat automatically controls the cooling 
cycle (compressor) of the air conditioner to maintain
room temperature. However, the fan motor will
continue to operate after the compressor (cooling
cycle) is completed. See Fig.9. 

Operating Instructions

 9

Mechanical control model

Fig.10

Fresh Air 
Vent Lever

Fresh Air Ventilation

 is usually kept in the closed

position. Use only when clearing smoke and/or
odors from the room. Pull to open. (See Fig.10). 

Summary of Contents for SCA062RWB1

Page 1: ...User s Manual 5 850 BTU Room Air Conditioner Model SCA062RWB1 20060316...

Page 2: ...ontents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide 1 Page 2 2 4 5...

Page 3: ...tructions completely before starting This manual contains information for the installation and operation of your room air conditioner Cabinet Exterior Air Inlet Interior Air Outlet Control Knob Note T...

Page 4: ...onsequently the shape may differ from that of the air conditioner you have selected Power Cord Front Panel Horizontal Air Vane Vertical Air Vane Fresh Air Lever for 8K model only Interior Air Inlet Gr...

Page 5: ...ing plate on the unit contains electrical and other technical data The rating plate is located on the right side of the unit If the air conditioner has a serial plate rating of 115 volts and up to and...

Page 6: ...utdoor temperature is cool enough use HIGH or LOW FAN only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting 2 5 Screws 8...

Page 7: ...For maximum efficiency install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight it is advisable to provide an awning over t...

Page 8: ...the guides of the air conditioner Fasten the curtains to the unit with screws Fig 2 Fig 3 3 Cut the adhesive backed seal strip the window width Remove the backing from the seal strip and attach the se...

Page 9: ...ix top channel to widow sash with one 3 4 screw and fix side curtain frames with four 3 4 screws as shown in Fig 6 Fig 6 Fig 7 About 5 L Bracket Seal 7 If storm window presents interference fasten a 2...

Page 10: ...tomatically with minimum air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW...

Page 11: ...fan speed Cooling Fan only Display set temp Display set timer Timer Energy saving Indication symbols of LED on control panel Fan Speed button Used to select fan speed in sequence auto low medium and...

Page 12: ...ol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the mid same as low mode fan speed 6 Low BUTTON Used to select the low mode fan speed 7 Auto BUTTON Used to select t...

Page 13: ...rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim 12 To operate the room air conditioner aim the remote control to the signal receptor The remote co...

Page 14: ...sp the filter handle tab located on the up center side of the air inlet grille and slide the air filter to the up To reinstall the air filter reverse the above procedure DO NOT forget to install the a...

Page 15: ...tside Unit must be installed on an angle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot...

Page 16: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Reviews: