F i b e r O p t i c S o l u t i o n s P r o v i d e r
2/8
www.suntelecom.cn • +86-21-60138638 • [email protected]
Protection Rating
IP65
Operating
Temperature (°C)
-40~ +60
Dimensions (mm)
1450(H) x 750(W) × 320(D)
Weight (kg)
119
2
The installation of the cabinet
2.1 The installation and debugging of the cement
2.1.1
Prefabricate the cement as picture 1 below.
picture 1
Dimension of the cement(H*L*W): 810mm
×
410mm
×
200mm
Leave a 450mm
×
200mm
×
200mm hole for the wire to entry in the
foundation center.
2.1.2
. Pre-embed ground screws and ensure the center length of the ground
screw to be 550mm × 270mm and at the same time the screw is 50mm above
ground. (The expansion bolt is also available here.)
2.1.3
. Put the cabinet on the cement and make sure the fixing hole is aligned
to the ground screw.
2.1.4
. In the case of the existing cement, four M17
×
100 expansion screws is
enough to do the fixing.
2.2 The installation and the debugging of the cabinet base
When adopt matched-installation, the base can be fixed on the cement first
according to the actually situation and then connected to fixing base of the