Servicing CRUs That Require Server Power-Off
77
1. Prepare the server for service.
a. Power off the server and disconnect the power cords from the power
supplies.
See
“Powering Down the Server” on page 33
.
b. Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 39
.
c. Attach an antistatic wrist strap to your wrist and then to a metal area on the
chassis.
See
“Take Antistatic Measures” on page 42
.
d. Remove the server top cover.
See
“Remove the Server Top Cover” on page 43
.
2. Select the PCIe riser that you want to remove.
See
“PCIe Slot Characteristics” on page 85
.
3. If a PCIe card is installed in the riser, disconnect any external or internal cables
from the card.
4. Lift the green-tabbed latch on the rear of the server chassis next to the
applicable PCIe slot to release the rear bracket on the PCIe card [1].