88
Sun Server X4-2 Service Manual • May 2014
b. Disconnect the rear bracket attached to the PCIe card from the rear of the
PCIe riser.
3. Place the PCIe card on an antistatic mat.
Caution –
Whenever you remove a PCIe card, you should replace it with another
PCIe card or a PCIe filler panel. Installing PCIe filler panels in vacant PCIe slots
helps reduce the level of electromagnetic interference (EMI) emitted by the server.
For instructions for installing PCIe filler panels, see
“Removing and Installing Server
Filler Panels” on page 143
.
▼
Install a PCIe Card in PCIe Slot 3
1. Retrieve the PCIe card and riser you to install.
2. Insert the rear bracket that is attached to the PCIe card into the PCIe riser.
3. Hold the riser in one hand and use your other hand to carefully insert the PCIe
card connector into the riser.