Servicing FRUs
135
c. Close the processor ILM assembly load plate [4 and 5].
d. Repeat
Step a
through
Step c
above to install the second processor socket
cover on the faulty motherboard.
Related Information
■
“Install the Motherboard” on page 135
▼
Install the Motherboard
Caution –
The motherboard should be installed only by an Oracle qualified service
technician.
1. Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Take Antistatic Measures” on page 42
.
2. Install the motherboard into the server chassis [1].
a. To install the motherboard into the server, grasp the middle of the air duct in
the front and back and tilt the front of the motherboard up slightly and push
it into the opening in the rear of the server chassis [1].
b. Lower the motherboard into the server chassis and slide it to the rear until it
engages the six mushroom-shaped standoffs located on the server chassis
under the motherboard [1].