![Sun Oracle Storage Tek T10000 Reference Manual Download Page 210](http://html1.mh-extra.com/html/sun-oracle/storage-tek-t10000/storage-tek-t10000_reference-manual_1393179210.webp)
Request Sense Command
192
T10000: Interface Reference Manual • January 2011
• E20425-01
Table 148. Progress Indication Sense Key Not Ready or No Sense Specific Data
Byte
Bit
7
6
5
4
3
2
1
0
0
SKSV
Reserved
1
thru
2
(MSB)
Progress Indication
(LSB)
Parameter
Value
SKSV:
Sense Key Specific Fields Valid
0 = Progress indication not valid
1 = Progress indication valid. Only set when sense key is 0.
Progress Indication
Percent complete
0000h to FFFFh
FSC-1
Fault Symptom Code for the first error encountered while
attempting the requested operation.
The FSC codes are specific to the T10000 tape drives.
FSC-2
Fault Symptom Code for second error encountered.
FSC-3
Fault Symptom Code for last error encountered.
TapeType
Identifies type of tape currently loaded in drive.
1000b = Cleaning tape
0100b = Dump tape
0010b = Code load tape
0001b = Data tape
0000b = Unknown type
DAvail
Diagnostic information is Available
MIRBad
Metadata on the currently loaded tape is defective
Volsafe
Current tape is append only
TapeEOL
Tape currently loaded is at End Of Life (EOL)
LibAtt
Drive is Attached to a library
Summary of Contents for Storage Tek T10000
Page 14: ...Tables xiv T10000 Interface Reference Manual January 2011 E20425 01...
Page 18: ...What s New xx T10000 Interface Reference Manual January 2011 E20425 01...
Page 82: ...Private Loop SCSI Target Discovery 64 T10000 Interface Reference Manual January 2011 E20425 01...