Chapter 2
Installing the Sun Fire T2000 Server
19
11. Slide the chassis into the rack.
Caution –
Verify that the server is securely mounted in the rack, and that the slide
rails are locked to the mounting brackets, before continuing.
▼
To Install the Cable Management Kit
The cable management assembly (CMA) clips into the ends of the left and right
sliding rail assemblies. No screws are necessary for mounting the CMA.
Caution –
Support the CMA during this installation. Do not allow the assembly to
hang by its own weight until it is secured by all three attachment points.
1. At the rear of the rack, plug the CMA rail extension into the end of the left sliding
rail assembly (
). The tab at the front of the rail extension will click into
place.