D-6
Sun StorEdge L400 Installation and User’s Guide • April 1998
72
FRONT DOOR OPEN. The front door
is open or the door solenoid is
malfunctioning.
Close and lock the door.
If the error still appears, make sure the library and
tape drives are not being used by any host, then
press Reset on the operator panel.
If the error persists, contact your service provider.
73
S SERVO TIMEOUT. The CHM could
not reach its destination along the
short axis.
Open the door. Look for anything that might be
obstructing the CHM along its short axis.
Make sure the tape library and the tape drives are
not being used by the host computer, then press
Reset on the operator panel. If the error still occurs,
contact your service provider.
75
INTERNAL S/W ERROR. Firmware
error.
Make sure the tape library and the tape drives are
not being used by the host computer, then press
Reset on the operator panel.
If the error still occurs, contact your service provider.
You may be asked to supply a diagnostic listing, and
you may need new firmware.
76
POS ERROR TIMEOUT. The CHM
could not reach its destination along
the long axis.
Open the door. Look for anything that might be
obstructing the CHM along its long axis.
Make sure the tape library and the tape drives are
not being used by the host computer, then press
Reset on the operator panel. If the error still occurs,
contact your service provider.
77
INTERFACE DISABLED. The tape
library was not in correct control mode
when a command was sent.
Make certain you have set the correct control mode.
If the control mode is correct, contract your service
provider.
90
INVALID BLANK CONFIG. The drive
blank configuration is invalid.
If you operate the tape library with only one drive,
you must have a drive blank installed in the
outermost slot.
91
OPERATOR ABORTED. A diagnostic,
in progress, was aborted.
No corrective action required.
97
DRIVE NOT INSTALLED. The tape
drive could not be cleaned because no
tape drive is installed in this location.
This error only appears on the Clean Drives Menu. If
no tape drive is installed in the location, redirect the
CHM. If a tape drive is installed, make sure that the
drive carrier is correctly seated. If the error persists,
contact your service provider.
TABLE D-1
Hardware Errors by Error Code (Continued)
Error
Number
Description
Corrective Action
Summary of Contents for StorEdge L400
Page 24: ...xxiv Sun StorEdge L400 Installation and User s Guide April 1998 ...
Page 30: ...1 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Page 86: ...6 14 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Page 140: ...C 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Page 162: ...Index 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...