5-12
Sun StorEdge 3000 Family Installation, Operation, and Service Manual • March 2004
Important rules to remember are:
■
A single logical drive can be mapped to only one controller, either the primary
controller or the secondary controller.
■
In a point-to-point configuration, only one host ID per channel is allowed. The
host ID can be assigned to the primary controller and be a PID, or it can be
assigned to the secondary controller and be a SID.
■
If you have two switches and set up multipathing (to keep all logical drive
connections operational for any switch failure or the removal of any I/O
controller module), ensure that each logical drive is mapped to two ports, one on
each I/O controller module, and on two channels. The cables from the two ports
mapped to each logical drive must be cabled to two separate switches. See
for an example of this configuration.
shows the channel numbers (0, 1, 4, and 5) of each host port and the host
ID for each channel. N/A means that the port does not have a second ID
assignment. The primary controller is in the top I/O controller module, and the
secondary controller is in the bottom I/O controller module.
The dashed lines between two ports indicate a port bypass circuit that functions as a
mini-hub and has the following advantages:
■
The port bypass circuit on each channel connects the upper and lower ports on
the same channel and provides access to both controllers at the same time.
■
If there are two host connections to the upper and lower ports on Channel 0,
and one host connection is removed, the other host connection remains
operational.
■
Therefore, if you have a redundant multipathing configuration in which you
have two host connections to each logical drive and one connection fails, the
remaining path maintains a connection to the logical drive.
In
, with multipathing software to reroute the data paths, each logical
drive remains fully operational when the following conditions occur:
■
One switch fails or is disconnected, and the logical drive is routed to the second
switch. For example, if switch 0 fails, switch 1 automatically accesses logical drive
0 through the cabling to the lower port on PID 41.
■
One I/O controller module fails, and all the host IDs for that controller are
reassigned (moved) to the second 1/O controller module. For example, if the
upper I/O controller module is removed, host IDs 40 and 41 are automatically
moved to the lower module and are managed by the second controller.
■
An I/O controller module fails or one cable is removed from an I/O controller
module, and all I/O traffic to the disconnected channel is rerouted through the
second port/host LUN assigned to the logical drive. For example, if you remove
the cable to channel 4, the data path for logical drive 1 switches to the port on
channel 5.
Summary of Contents for StorEdge 3000 Series
Page 14: ...xiv Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 18: ...xviii Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 38: ...1 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 48: ...2 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 54: ...3 6 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 140: ...5 62 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 180: ...7 32 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 208: ...8 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 242: ...B 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 252: ...D 8 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 270: ...G 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 280: ...H 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Page 312: ...K 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...