Sun Netra X4450 Server Service Manual • August 2008
FIGURE 3-13
Removing FB-DIMMs
3. Grasp the top corners of the faulty FB-DIMM, and remove it from the memory
mezzanine.
4. Place the FB-DIMM on an antistatic mat.
5. Repeat
Step 2
through
Step 4
to remove any additional FB-DIMMs.
▼
Install FB-DIMMs
Caution –
Ensure that all power is removed from the server before removing or
installing FB-DIMMs or damage to the FB-DIMMs might occur. You must disconnect
the power cables from the system before performing this procedure.
1. If you are adding memory, prepare the server for service.
See
Chapter 2
.
2. Unpackage the FB-DIMMs, and place them on an antistatic mat.
3. Ensure that the ejector tabs are in the open position.
4. Line up the replacement FB-DIMM with the connector (
FIGURE 3-14
).
Align the FB-DIMM notch with the key in the connector. This ensures that the
FB-DIMM is oriented correctly.