88
Sun Datacenter Switch 3456 Installation Guide • December 2008
Powering On the CMCs
When standby power is applied to the chassis, the CMCs are powered on. In the
presence of standby power, the CMCs cannot be powered off. However, you can
enable and disable the management capabilities of the CMCs.
▼
To Cable CMCs to the Management Console
A serial connection enables you to interact with the CMC. The SER MGT connector
is a standard RS-232 port, with communication parameters 115200,8,N,1.
●
Use a serial terminal, a TIP connection, or a terminal server as a means of
communicating with the CMC. See
FIGURE 10-4
CMC External Features
▼
To Access the CMC From the Serial Management Port
1. If you have not already done so, connect a serial terminal, terminal server, or
workstation with a TIP connection to the serial management port of the CMC.
Configure the terminal or terminal emulator with these settings:
■
115200 baud
Figure Legend
1
Release levers
2
Serial management ports
3
Network management ports
4
Status LEDs
1
2
3
4
Summary of Contents for Datacenter Switch 3456
Page 10: ...x Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 14: ...xiv Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 20: ...6 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 48: ...34 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 49: ...Chapter 5 Unpacking the Chassis 35 ...
Page 73: ...58 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 87: ...72 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 97: ...82 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Page 125: ...110 Sun Datacenter Switch 3456 Installation Guide December 2008 ...