ILOM Supplement for Sun Blade X6220 Server Module
21
Fan Sensors
The server module contains six fan modules labeled fm[0-5]. Each module contains
two fans.
fm[0..5].f[0..1].speed
All top-accessable fan speed sensors are configured to generate the same events and
all faults are handled in the same way. They are not monitored when the host is
powered off.
fm[0..5].fail
This is a GPIO signal indicating fan module failure status.
CPU [0..1] and DIMM Sensors
There are two CPUs per server module.
TABLE 17
fm[0..5].f[0..1].speed
Threshold
Direction
Event
Description
Lower Non-
Recoverable
Assert
Yes
Fan speed has decreased below lower non-recoverable
threshold.
This indicates that the fan has failed or has been
removed.
Lower Non-
Recoverable
Deassert
Yes
Fan speed has returned to normal from lower non-
recoverable.
This indicates that the fan has returned to normal or
has been replaced.
TABLE 18
fm[0..5].fail
Reading
State
Event
Description
0x0001
Predictive Failure
Deasserted
No
This state indicates that the fan module has not
failed.
0x0002
Predictive Failure
Asserted
Yes
This state indicates that the fan module has
failed.