![Sun Microsystems Blade X6220 Manual Download Page 25](http://html1.mh-extra.com/html/sun-microsystems/blade-x6220/blade-x6220_manual_1392493025.webp)
ILOM Supplement for Sun Blade X6220 Server Module
19
ps[0..1].vinok[0..1]
For each power supply module, there are two AC input lines. These sensors indicate
the status of input lines for each power supply.
ps[0..1].pwrok[0..1]
For each power supply module, there are two independent 12 volt DC outputs
generated from two AC inputs. These sensors indicate whether the DC output is on.
HDD Sensors
Each server module can support four hard drives. A number of sensors provide
information about each.
hdd[0..3].prsnt
These sensors monitor the hard disk hardware presence signal.
TABLE 12
ps[0..1].vinok[0..1]
Reading
State
Event
Description
Action
0x0001
State Deasserted
Yes
Power Supply is disconnected
from AC power.
System Alert LED
is SLOW
0x0002
State Asserted
Yes
Power Supply is connected to
AC power.
System Alert LED
is OFF
TABLE 13
ps[0..1].pwrok[0..1]
Reading
State
Event
Description
0x0001
State Deasserted
Yes
DC output is off.
none
0x0002
State Asserted
Yes
DC output is on.
none
TABLE 14
hdd[0..3].prsnt
Reading
State
Event
Description
0x0001
Device Absent
No
Hard drive is absent.
0x0002
Device Present
No
Hard drive is present.