4
ILOM Supplement for Sun Blade 6220 Modular Server • April 2007
You can connect to the ILOM on your server module using one of the following
methods:
■
Option 1 – When the server module is installed in a chassis, it is automatically
connected to the same subnet as the CMM ILOM. This allows you to use Ethernet
to connect to both the WebGUI andthe Command Line Interface (CLI).
Note –
The CMM ILOM in the chassis has an Ethernet switch that supports
connections to the server modules and their ILOMs. To use this connection, you
must be connected to the same subnet as the ILOM, and you must know the server
module ILOM’s Ethernet address.
■
Option 2 – Use the serial connector on the chassis to connect to the chassis CMM
ILOM. Then use the CMM ILOM to navigate to the server module. This
connection supports CLI access only.
■
Option 3 – Use a dongle cable to establish a serial connecton directly to the server
module. This connection supports CLI access only.
The following sections describe each of these methods.
shows the
connections.