Figure 5–25
NVRAM Location
2. Hold the NVRAM chip carrier on both ends and lift it straight up.
Gently wiggle the chip carrier as necessary.
3. Put the NVRAM in its chip carrier on an antistatic surface.
It is to be sent back with the defective system board to Sun.
Installing the NVRAM Chip
1. Locate the NVRAM chip and remove it from the defective system board.
See Figure 5–25.
2. Carefully align the pins and insert the NVRAM chip into the socket on the
MLB in the chassis.
The carrier is keyed so the NVRAM can be installed only one way.
3. Push the NVRAM chip into the carrier until it sits tightly in the socket.
60
SPARCstation 10 Service Manual
♦
Revision A, July 1993
Summary of Contents for 1.0
Page 2: ...USA 650 960 1300 fax 650 969 9131 ...
Page 3: ...SPARCstation 10 Service Manual Part No 800 6358 11 Revision A July 1993 ...
Page 16: ...xv SPARCstation 10 Service Manual Revision A July 1993 ...
Page 21: ...Figure 1 6 Exploded View of the SPARCstation 10 System MLB System Overview 5 ...
Page 26: ...Figure 2 1 Default Boot Mode Flowchart 10 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 54: ...38 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 88: ...72 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 104: ...88 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 112: ...96 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 120: ...104 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 190: ...174 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 198: ...182 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 202: ...186 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 214: ...198 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 220: ...Glossary 204 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 221: ...Index Index 205 ...