APPENDIX
A
System Specifications
This appendix contains the input power requirements, environmental requirements,
physical dimensions, packaging dimensions, and regulatory compliance information.
Power Input Requirements
Table A–1 lists the power input requirements for the system unit. The maximum
power dissipated is less than, or equal to, 187 watts. The power supply automatically
selects the correct AC voltage range.
TABLE A–1
Power Input Requirements and Power Dissipation for the System Unit
Operating
Voltage
Range
Maximum
Input
Current
Maximum
Input Power
Maximum
Input Volt-
Amperes
Thermal
Dissipation
Operating
Frequency
Range
100 – 240 Vac
6A
187W
200W
406 BTU
47 – 63 Hz
Environmental Requirements
Table A–2 lists the environmental requirements for the operating environment and
the non-operating environment.
175
Summary of Contents for 1.0
Page 2: ...USA 650 960 1300 fax 650 969 9131 ...
Page 3: ...SPARCstation 10 Service Manual Part No 800 6358 11 Revision A July 1993 ...
Page 16: ...xv SPARCstation 10 Service Manual Revision A July 1993 ...
Page 21: ...Figure 1 6 Exploded View of the SPARCstation 10 System MLB System Overview 5 ...
Page 26: ...Figure 2 1 Default Boot Mode Flowchart 10 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 54: ...38 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 88: ...72 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 104: ...88 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 112: ...96 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 120: ...104 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 190: ...174 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 198: ...182 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 202: ...186 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 214: ...198 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 220: ...Glossary 204 SPARCstation 10 Service Manual Revision A July 1993 ...
Page 221: ...Index Index 205 ...