18
Refer to Fig.1 Page 17
1. As described in the prior section, unplug unit and open access door
(swings up).
2. Remove dehumidistat knob (3) by gently pulling it forward.
3. Remove wire leads from terminal strip by loosening securing screws in front
of terminal strip. Be sure to identify leads and location prior to removing to
ensure they are returned to the correct location.
4. Remove front cover securing screws (1) and front cover (2).
5. Using a small brush (i.e. toothbrush), clean the wheel blades. Caution must be
exercised not to disturb the balancing weights on the wheel blades.
6. Reassemble.
7. Reconnect the power supply to the fan motor.