HOW THE EAR THERMOMETER TAKES A READING

The Grow With Me Ear Thermometer measures the heat radiated from the 

eardrum and the surrounding tissue. This energy is collected through the lens and converted 

to a temperature value equivalent to the commonly used oral reading. The measured reading 

obtained directly from the eardrum (Tympanic Membrane) can ensure the most accurate body 

temperature. The accuracy of a reading will depend on your technique, so please follow instruc-

tions for use carefully. We recommend that you practice using the ear thermometer on yourself 

and your family members when they are healthy. You will then be more confident using the ear 

thermometer when a family member is ill.

The Grow With Me Ear Thermometer meets the ASTM Accuracy Standard under normal 
operating conditions.

The Grow With Me Ear Thermometer has been clinically tested and proven to be safe and 
accurate when used in accordance with operating instructions.

WHAT IS A NORMAL TEMPERATURE?

 Normal Temperature Range by Age:
Age 

Fahrenheit 

Celsius

0-2 

97.5°F - 100.4°F 

36.4°C - 38.0°C

3-10 

97.0°F - 100.0°F 

36.1°C - 37.8°C

11-65 

96.6°F - 99.7°F 

35.9°C - 37.6°C

> 65 

96.4°F - 99.5°F 

35.8°C - 37.5°C

DIRECTIONS FOR USE

Note:
 • The thermometer probe should be kept clean by using alcohol swab to wipe it 2 minutes prior 
   to the test, and after each use.  
    

Dirt, dust, or ear wax on the sensor will give inaccurate measurements!

 • Do not touch the thermometer probe 2 minutes before measuring the ear.
 • The time interval of the continuous measurement for the same ear should be at least 15 seconds.
 • The thermometer probe should be fitted into the ear canal deep enough with gentle insertion, 
   making sure you don’t move the thermometer, then press the start key to get the measurement, 
   do not remove the probe until hearing a beep sound.

1.  Press the O/I button once to turn the ear thermometer on. The display will show all icons 
  momentarily while the ear thermometer runs a test.

2.  Then the last measurement reading will appear on the display for about 2 seconds. 
  You will see a small “M“ next to the temperature reading. 
  This memory feature helps you track your child’s progress.

3.  The ear thermometer will beep and the °F or °C icon will flash, 
  indicating that the thermometer is ready to take a reading.

4.  Straighten the ear canal by pulling the outer ear up 
  and back to give a clear view of the eardrum.
  •  For children under 1 year: Pull the ear straight back.
  •  Children ages 1 year to adult: Pull the ear up and back.
  •  For an infant, it is best to have 
    the child laying flat with head 

    sideways so the ear is facing 

    towards you. For an older child 

    or adult, it is best to stand 

    behind and slightly to the side.

5.  While gently pulling the ear, insert 
  the probe snugly into the ear canal
  and press the "START” button until 
  you hear a beep sound. You should 
  hear this beep after about 1 second; 
  It indicates the reading is complete.

6.  Remove the thermometer from the ear canal. Read the temperature measurement on the display.

NOTE:

•  Always take measurements in the same ear since temperature readings may be different from 

the right and left ear.

•  In order to assure accurate readings, please wait at least 15 seconds between continuous 

measurements.

•  In the following situations it is recommended that three temperatures in the same ear be taken 

and the highest one taken as the reading: 

1)  Newborn infants in the first 100 days.
2)  Children under three years of age with a compromised immune system and for whom the 

presence or absence of fever is critical.

3)  When you are learning how to use the ear thermometer for the first time and until you have 

familiarized yourself with the instrument and how to obtain consistent readings.

•  The LCD display automatically glows red when a fever temperature is detected. 
  Glows green for normal temperature.

5

DIRECTIONS FOR USE 

(CONTINUED)

• Whenever putting on (or removing) the adult adaptor, you need to wait for 2 more minutes to 

  cool down the probe so as to get a reliable reading for next measurement. The adult 

  adaptor should be assembled to the probe by hearing (or feeling) a small click sound, so  

  that we can ensure a reliable measurement.

• The adult adaptor is not necessary to put on unless it is for measuring the temperature of 

  an adult. 

• There may be some inconsistent readings between different continuous measurements, due to 

  the following reasons:

 

• Different probe insertion depth (or angle).

 

• Too frequent measurement for the same ear within a short period of time  

 

   (more than 5 times, with time interval less than 5 sec.). 

 

• Extreme ambient temperature change, dirty probe with ear wax or dust, dirty ear canal.

 

• Long stay of the probe inside the ear canal (should not be more that 5 sec.), probe 

 

   shaking during measuring or probe removing away from ear before hearing the beep.

COMPONENTS

Less than
1 year old

1 year and older, 
including adults

Normal body temperature varies from person to person. 

It is important to be familiar with 

your and your child’s healthy 

temperature range to help you

identify what is normal. You can 

do this with your Grow With Me

Ear Thermometer. Please 

note that ear, oral, rectal and 

underarm temperature readings 

also vary, therefore readings 

taken from different body sites 

should not be directly compared.

4

Summary of Contents for Grow With Me 03110

Page 1: ...evelopment and curvature of the ear canal QUICK START GUIDE 1 2 3 4 Please Note Unit Reads Oral Equivalent Temperature Take 3 or More Measurements Especially if Readings Appear Low GROW WITH ME EAR THERMOMETER TABLE OF CONTENTS Product Features Page 3 Important Safety Instructions Page 3 Components Page 4 How the Ear Thermometer Takes a Reading Page 4 What is a Normal Temperature Page 4 Directions...

Page 2: ...NT SAFETY INSTRUCTIONS Never use the thermometer for purposes other than body temperature measurement Please follow the safety precautions when using on children Never immerse the ear thermometer in water or other liquids not waterproof For cleaning and disinfecting please follow the instructtions in the Cleaning and Storage section Keep the instrument away from direct exposure to the sun and keep...

Page 3: ...8 C 11 65 96 6 F 99 7 F 35 9 C 37 6 C 65 96 4 F 99 5 F 35 8 C 37 5 C DIRECTIONS FOR USE Note The thermometer probe should be kept clean by using alcohol swab to wipe it 2 minutes prior to the test and after each use Dirt dust or ear wax on the sensor will give inaccurate measurements Do not touch the thermometer probe 2 minutes before measuring the ear The time interval of the continuous measureme...

Page 4: ...ollowing situations it is recommended that three temperatures in the same ear be taken and the highest one taken as the reading 1 Newborn infants in the first 100 days 2 Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical 3 When you are learning how to use the ear thermometer for the first time and until you have familiarized...

Page 5: ...w battery What to Do Wait for memory display Wait for ready display Insert ear thermometer into ear and press START button Read temperature See instructions on page 7 for Replacing the Battery LCD Display Display Meaning Measured temperature too high Measured temperature too low Ambient temperature too high Ambient temperature too low Possible Cause and Fault Remedy Probe may not have been inserte...

Page 6: ...l Display with indicating unit 0 1 C 0 1 F 7 REPLACING THE BATTERY The Grow With Me Thermometer is supplied with one lithium battery type CR2032 Replace with a new CR2032 battery when the flashing battery symbol appears on the LCD display Use a toothpick or insulated probe to remove the battery Do not use any kind of sharp metal object to remove the battery BATTERY WARNING Keep battery out of chil...

Page 7: ...gital Infrared Thermometer a The unit is turned ON and ready for the measurement 1 short beep sound b Complete the measurement 1 long beep sound 1 sec if the reading is less than 99 5 F 37 5 C 10 short beep sounds if the reading is equal to or greater than 99 5 F 37 5 C c System error or malfunction 3 short beep sounds Auto Displays the last measured temperature when switched on a The LCD display ...

Reviews: