![Summa SummaCut D120 User Manual Download Page 44](http://html.mh-extra.com/html/summa/summacut-d120/summacut-d120_user-manual_1390733044.webp)
SummaCut cutter
User’s Manual
Basic Operation
2-10
1
2
FIG 2-7
2-3
LENGTH CALIBRATION PATTERN
NOTE:
The cutter will only be as accurate as the accuracy of the calibration. If the
ruler (measuring device) is inaccurate, then re-calibrating may make the cutter’s
accuracy worse. The accuracy of calibration will be directly reflected in the cuts. Set
the cutter to Metric to do the calibration. It is more accurate than the English unit
system (see
Error! Reference source not found.
).
7.
Use
,
,
and
to change the value on the LCD to the measured
length of the distance between the two lines down the length of the vinyl roll.
Value will change on the LCD.
8.
Press
to confirm.
Value for the Y axis will appear on the LCD.
9.
Use
,
,
and
to change the value on the LCD to the measured
length of the distance between the two lines down the width of the vinyl roll.
10.
Press
to confirm.
11.
Press