background image

 

Copyright © 2020 Sumitomo Heavy Industries,Ltd. All rights reserved. 

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or 
transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, 
without the prior written permission of Sumitomo. No patent liability is assumed with respect to the use of 
the information contained herein. Moreover, because Sumitomo is constantly striving to improve its 
high-quality products, the information contained in this manual is subject to change without notice. Every 
precaution has been taken in the preparation of this manual. Sumitomo assumes no responsibility for 
errors or omissions. Neither is any liability assumed for damages resulting from the use of the information 
contained in this publication. 
 

Summary of Contents for HF-430NEO P1-AG

Page 1: ...SMIT Via dell Artigianato 23 20010 Cornaredo MI Italy TEL 39 293 481101 FAX 39 293 481103 Spain SM Cyclo Iberia S L U SMIB C Gran V a N 63 Bis Planta 1 Departamento 1B 48011 Bilbao Vizcaya Spain TEL 3...

Page 2: ...mitomo No patent liability is assumed with respect to the use of the information contained herein Moreover because Sumitomo is constantly striving to improve its high quality products the information...

Page 3: ...ng and operation instructions is required Please follow all the specifications and instructions for a proper use Additionally periodically review the HF 430NEO Instruction manual and User s Guide the...

Page 4: ...apter 7 1 7 2 Self diagnosis 7 1 8 1 About this chapter 8 1 Warranty App 1 1 1 3 Symbol explanation 1 2 1 4 Precautions 1 2 2 4 Guide objectives 2 1 2 5 Guide outline 2 2 3 3 Name plate 3 1 3 4 Dimens...

Page 5: ...dangerous situation that have a high risk of causing death serious injuries and or major property damage Warning This category warns the user that in case of an incorrect or improper handling it lead...

Page 6: ...s that must be done based on the instructions 1 4 Precautions 1 4 1 Please be careful If handled incorrectly or improperly it might cause death serious physical injuries or damage to the inverter moto...

Page 7: ...on this device When handling the object avoid places prone to static electricity like carpets Since the human body can get charged with static electricity as a safety measure please touch a safe meta...

Page 8: ...sed from the case of this product Risk of Fire Please tighten the screws and bolts with the specified torque Please refer to the inverter user s guide Verify that none of the screws and bolts are loos...

Page 9: ...cturer that the motor or the equipment can tolerate the high frequency output given by the inverter During operation verify the motor rotation direction and that there are no irregular sounds or vibra...

Page 10: ...industrial waste collector transporter and industrial waste disposal operator Follow all laws and decrees related to procedures of waste management and public cleansing when disposing of this device...

Page 11: ...o the P1 AG device For information about the inverter please refer to the HF 430NEO user s guide or the instruction manual 2 3 Before reading this guide This guide is aimed for people who purchase han...

Page 12: ...ures The chapter 4 Enclosed Items Enclosed Items contains information about the items included with this device The chapter 5 Installation and Wiring Installation and Wiring contains information for i...

Page 13: ...omenclature An external view of this device is shown below For installing this device connectors and other parts refer to the chapter 5 Installation and Wiring 3 3 Name plate The P1 AG name plate give...

Page 14: ...ter it is installed on the HF 430NEO are shown in the image below As shown on the image a part of this device will stand out from the HF 430NEO Please be cautious when installing the P1 AG HF 430NEO I...

Page 15: ...after the purchase 4 3 1 Verification when unpacking Please verify the items written on the right when unpacking In case there is any doubt or trouble with the product please contact your sales agent...

Page 16: ...the HF 430NEO user s guide Additionally when doing any work or operation always follow the safety instructions and cautions given in the chapter 1 5 2 Installation 5 2 1 Installation The P1 AG can be...

Page 17: ...keep it in a safe place However the screw that secured the cover will be used to secure the P1 AG 2 Attach the P1 AG The slots 2 and 3 have one more connection in the lower side However the P1 AG wil...

Page 18: ...ew removed in procedure 1 4 Connect the FG terminal to functional ground Option cassette connection slots Keypad RJ45 USB micro B SLOT1 SLOT2 SLOT3 Fasten the screw Option cassette connection slots Ke...

Page 19: ...witch Si5 Select input 5 voltage or current Shorted Si5 to L Vi5 enabled initial condition Opened Si5 Ii5 enabled Analog Input Terminal 6 Vi6 Voltage 6 10 to 10V Input impedance 10k approximately allo...

Page 20: ...e order of removal method Pulling out the wire Pressing the grey part 3 on P1 AG connector with flat screwdriver width 2 5mm or less to open the wire port Pulling out the wire or the ferrule terminal...

Page 21: ...ultipoint ground Make sure that length of wiring to P1 AG must be 20 m or less In case the length is more than 20 m the inverter may malfunction caused by external noise Make sure of wiring the FG ter...

Page 22: ...width AJ 07 PID2 set point input source selection oE 44 Ai4 Operation level at disconnection AJ 12 PID2 feedback input source selection oE 45 Ai4 Operation level selection at disconnection AJ 27 PID3...

Page 23: ...G manufacture number MFG No 5 Date of purchase 6 Inquiry contents For information about how to check the 1 and 2 refer to the HF 430NEO user s guide For information about how to check the 3 and 4 refe...

Page 24: ...on 1 Error 8 E078 Option 2 Error 8 E088 Option 3 Error 8 In case the P1 AG is attached to the unsupported inverter E068 E078 or E088 is shown as the error code Those error codes E06 E07 or E08 depend...

Page 25: ...tion The function of analog input output does not work properly The P1 AG is not correctly attached When a communication error occurring between the P1 AG and the inverter the P1 AG outputs 0V or 0mA...

Page 26: ...ng humidity 20 to 90 RH Storage temperature 1 20 to 65 Vibration resistance 5 9 m s2 0 6G 10 to 55 Hz Conformance to EMC and electrical safety standards IEC EN61800 3 Second environment Category C3 IE...

Page 27: ...1 Installation connection combination or integration of the Product in or to the other equipment or machine that rendered by any person or entity other than the Seller 2 Insufficient maintenance or i...

Page 28: ...SMIT Via dell Artigianato 23 20010 Cornaredo MI Italy TEL 39 293 481101 FAX 39 293 481103 Spain SM Cyclo Iberia S L U SMIB C Gran V a N 63 Bis Planta 1 Departamento 1B 48011 Bilbao Vizcaya Spain TEL 3...

Reviews: