![Sumitomo HF-430NEO P1-AG User Manual Download Page 20](http://html1.mh-extra.com/html/sumitomo/hf-430neo-p1-ag/hf-430neo-p1-ag_user-manual_1390646020.webp)
5-5
Chapter 5
Installation and Wiring
■
Recommendation terminals
In order to make convenience to wiring and improve the connection, it's recommended to use the ferrule
terminals with the following specifications for signal wire.
*1) Manufacturer:
PHOENIX CONTACT GmbH & Co. KG Crimping tool: CRIMPFOX® 6
Note that these specifications are different from the recommended ferrule terminals for the inverter.
■
Wiring
Inserting the wire:
①
Inserting the ferrule terminal into the P1-AG connector. It will be easy to insert without any tools if use
the recommendation ferrule terminals. *2)
*2) In case not using the recommendation ferrule terminal,
please insert it with a flat head screwdriver in the reverse
order of removal method.
Pulling out the wire:
①
Pressing the grey part *3) on P1-AG connector with flat screwdriver
(
width 2.5mm or less
)
to open
the wire port.
②
Pulling out the wire or the ferrule terminal while pressing the flat screwdriver.
③
Pulling out the flat screwdriver.
*3) It is orange of the actual color that grey part
on the connector.
■
Detaching the connector
Pulling down the latch lever in the arrow direction as shown below, then pulling out the connector.
Wire diameter
[mm
2
] (AWG)
Ferrule terminal
model *1)
L1[mm] L2[mm]
φ
d[mm]
φ
D[mm]
0.25 (24)
AI 0,25-10 YE
10.0
14.5
0.8
2.0
0.34 (22)
AI 0,34-10 TQ
10.0
14.5
0.8
2.0
0.5 (20)
AI 0,5-10 WH
10.0
16.0
1.1
2.5
0.75 (18)
AI 0,75-10 GY
10.0
16.0
1.3
3.4
Inserting wire
Pressing the grey part *3)
with flat screwdriver
Pulling out
the wire or
the ferrule terminal
Pulling out the flat
screwdriver
Pulling down the latch lever
Pulling out the connector