25
24
Common
8. Daily inspection and Maintenance
8-3 Oil Supply and Change for
Gear Part with Oil Lubrication
r
(1) Interval Oil Change
Table 10 Oil Change Interval
Task
Change interval
Conditions of use
Supply of oil
At purchase
common
Oil Change
First Change
500 hrs operation or 6 months, whichever comes first.
common
Second change and thereafter
5000 hrs operation or 1 year, whichever comes first.
Indoor temperature is 0-35°C
2500 hrs operation or 6 months, whichever comes first. Location where temperature cannot be kept at 0-35°C
In the case where the ambient temperature is high, there is intense change in temperature, or the air contains corrosive gas consult the oil producter.
These situations may accelerate the deterioration of the oil.
(2) Recommended Lubricants
Always use recommended lubricants shown in Table 11.
Table 11 Recommended lubricants (Equivalent to SP type industrial extreme-pressure gear oil or JIS K2219
Ambient
temperature °C
COSMO
ENEOS
IDEMITSU
Shell
Mobil
Gulf
CALTEX
bp
-10 to 5
COSMO
GEAR SE
68
BONNOC
M
68
−
Daphne
Super
Gear Oil
68
Shell Omala
S2 G
68
−
Mobilgear
600 XP
68
Gulf EP
Lubricant HD
68
–
Energol
GR-XP
68
0 to 35
COSMO
GEAR SE
100, 150
BONNOC
M
100, 150
BONNOC
TS
150
Daphne
Super
Gear Oil
100, 150
Shell Omala
S2 G
100, 150
Spartan EP
150
Mobilgear
600 XP
100, 150
Gulf EP
Lubricant HD
100, 150
Meropa
100, 150
Energol
GR-XP
100, 150
30 to 50
COSMO
GEAR SE
220 - 460
BONNOC
M
220 - 460
BONNOC
TS
220 - 460
Daphne
Super
Gear Oil
220-460
Shell Omala
S2 G
220 - 460
Spartan EP
220 - 460
Mobilgear
600 XP
220 - 460
Gulf EP
Lubricant HD
220 - 460
Meropa
220 - 460
Energol
GR-XP
220 - 460
1. Use lubricants with low viscosity for operation during winter or at relatively low ambient temperature.
2. Table 12 shows allowable viscosity of the lubricant. Use the lubricant with viscosity in this range.
Table 12 Allowable viscosities
Min. allowable viscosity
15 mm
2
/s or more at operating oil temperature
Viscosity that ensures oil film strengh adequate for load transmission
Max. allowable viscosity
Oil-bath lubrication
4300 mm
2
/s max.
Viscosity that permits start-up of Buddybox
3. Make sure that the pour point of the oil is lower than the ambient temperature, at least with 5˚C difference. This is for smooth
starting.
4. When the range of operating temperature is wide, use oil with high viscosity index. The oil should meet requirements above 2
and 3.
5. Consult us when operating the unit in ambient temperature other than 0-40˚C. Parts change and preheat or cooling of lubricant
is necessary for some models.