5
1 General
Basically the main parts of the installation and operating instructions with part no. 6006183 / 6005672 (ABS submersible mixer RW) are also
valid for
RW 480
. This also applies if the RW 480 model Ex is connected correctly and operated in safe mode. Same applies for the
Safety
instructions
. These are included in the separate booklet 1 597 0799 and have to be studied carefully before installation and commisioning!
These additional installation and operating instructions for ABS submersible mixer RW 480 contain only cross-references e.g. the
differing, additional and product-specific information.
1.1 - 1.3 Introduction; Correct usage of the product; Application restrictions
See chapter 1.1 - 1.3 of the Installation and Operating Instructions 6006183 / 6005672.
1.4
Application areas
The submersible mixer RW 480 is used for mixing, stirring and agitating of viscous fluids containing solids in sewage treatment plants,
industry, and agriculture. It is specifically designed for the major mixing fuctions during homogenization of sludge and coenzymes.
1.5
Identification code
See chapter 1.5 of the Installation and Operating Instructions 6006183 / 6005672. *Propeller type = 2-blade special propeller for sludge
and coenzymes.
1.6
Technical data
See chapter 1.6 of the Installation and Operating Instructions 6006183 / 6005672.
1.6.1
Technical data RW 480, 50 Hz
M
ix
er
ty
pe
Pr
op
el
ler
d
ia
-
m
et
er
Sp
ee
d / G
ea
r
rat
io
M
oto
r t
yp
e
R
at
ed p
ow
er
in
pu
t P
1
R
at
ed p
ow
er
ou
tp
ut
P
2
St
ar
tin
g: D
ire
ct
(D
.O.
L)
Sta
rti
ng
: S
ta
r/
D
el
ta
R
at
ed c
ur
re
nt
at 4
00
V
St
ar
tin
g cu
r-
re
nt a
t 4
00 V
C
ab
le
ty
pe*
*
(E
x- a
nd s
ta
nd
ar
d)
Te
mp
er
at
ure
m
oni
to
rin
g
Seal
m
on
ito
-
rin
g
E
x d
II B
T4
G
ui
de t
ub
e □
10
0
To
tal
w
ei
ght
[mm]
[1/min]
[kW]
[kW]
[A]
[A]
[kg]
RW 4811
480
446/3.3
A 75/4
8.66
7.5
●
14.84
93.9
2
●
●
○
●
163
RW 4812
480
467/3.1
A 75/4
8.66
7.5
●
14.84
93.9
2
●
●
○
●
163
RW 4813
480
493/3.0
A 75/4
8.66
7.5
●
14.84
93.9
2
●
●
○
●
163
RW 4814
480
517/2.8
A 110/4
13.0
11.0
●
21.85
103.4
2
●
●
○
●
169
RW 4815
480
554/2.6
A 110/4
13.0
11.0
●
21.85
103.4
2
●
●
○
●
169
1.6.2
Technical data RW 480, 60 Hz
RW 4811
480
503/3.5
A 90/4
10.2
9.0
●
15.32
103
2
●
●
●
163
RW 4812
480
535/3.3
A 90/4
10.2
9.0
●
15.32
103
2
●
●
●
163
RW 4813
480
561/3.1
A 130/4
15.0
13.0
●
21.88 119.9
2
●
●
●
169
P
1
=Power input; P
2
= Power output; ● = Standard; ○ = Option; **Cable type: 10 m cable with free ends as standard: 2 = 1 x 10G x 1.5
1.7
Dimensions and weights
See chapter 1.7 of the Installation and Operating Instructions 6006183 / 6005672.
1.7.1
Dimensions RW 480
1031
[40.6]
94
[3.7]
405
[15.9]
1127
[44.4]
min. 190
[min. 7.5]
405
[15.9]
□ 100
[□ 4]
ø 482 [19 dia]
min. 50 [min. 2]
ø 482 [19 dia]
109.6 [4.3]
ø 226 [8.9 dia]
312 [12.3]
47.5 [1.9]
□ 100
[□ 4]
mm
inch
min. 800
[min. 31.5 dia]
0551-0042
Figure 1 Dimensions RW 480
EN 6184-E
...
460
V
...
460
V