Section 5
TSR32 USER MANUAL R00
37
OPERATION
5.1
ROUTINE OPERATION
Before starting the compressor, check the fluid level
in the receiver tank. If the fluid level is not showing in
the sight glass, add the required amount of fluid up to
the mid-point to bring it to its proper level. Frequent
addition of fluid indicates the presence of a leak or a
condition causing excessive fluid consumption. See
Section 6.8: Troubleshooting Introduction
on page
43 under EXCESSIVE COMPRESSOR FLUID
CONSUMPTION for a probable cause and corrective
action.
After a routine start, observe the controller display for
the proper indications for this phase of operation.
After the compressor has warmed up, check all
compressor operation indications to ensure that it is
running properly.
WARNING
HIGH-PRESSURE HAZARD!
DO NOT remove caps, plugs, and/or other
components when compressor is running
or pressurized. Stop compressor and
relieve all internal pressure before doing so.
Failure to comply could result in death or
serious injury.