4. MAINTENANCE
4.1 CHECKLIST
These checks are to be carried out by the operator during the routine operations cycle.
4.1.1 D
AILY
C
HECK
Carry out a general visual check of fittings, listen for any sound which may
identify an air leak, and watch out for changes in indicated values during
operation
Read the
DEW POINT
display and check the maintenance record
Check function by manually operating the automatic condensate drain on the
prefilter.
NOTE: Should the need for spare parts or service arise during work on the
adsorption dryer, then the dryer model and serial number must be
conveyed to Sullair. This information is given on the nameplate mounted
on the control cabinet.
4.1.2 W
EEKLY
C
HECK
Check the incident monitor on the prefilter.
A value in the red suggests the
element has become blocked by excessive debris. Elements must be replaced
annually for proper performance regardless of the incident monitor reading (see
paragraph 4.2).
Check the incident monitor on the afterfilter. A value in the red suggests the
element has become blocked by excessive
debris.
Elements
must
be
replaced
annually for proper performance regardless
of the incident monitor reading.
Check the back pressure of the muffler
behind the inlet valve assembly by reading
the gauge on the chamber that is being
regenerated; it should not exceed 3 psig.
Drain
pilot
air
filter
housing
of
any
condensate (see figure 3).
Figure 3 – Pilot Air Filter
Summary of Contents for SD-1050 Series
Page 2: ...II...
Page 4: ...USER MANUAL Models SD 820 to SD 1710 with DDS Rev 04 October 2005 iv...
Page 29: ...USER MANUAL Models SD 820 to SD 1710 with DDS Rev 04 October 2005 23 7 DRAWINGS...
Page 30: ...USER MANUAL Models SD 820 to SD 1710 with DDS Rev 04 October 2005 24...
Page 34: ...USER MANUAL Models SD 820 to SD 1710 with DDS Rev 04 October 2005 B 2...
Page 35: ......