Section 1
SAFETY
2
death or serious injury may result.
1.4 FIRE AND EXPLOSION
A.
Clean up spills of lubricant or other combustible
substances immediately, if such spills occur.
B.
Shut off the compressor and allow it to cool.
Then keep sparks, flames and other sources of
ignition away and
DO NOT
permit smoking in the
vicinity when checking or adding lubricant or when
refilling air line anti-icer systems with antifreeze
compound.
C. DO NOT
permit fluids, including air line anti-icer
system antifreeze compound or fluid film, to accu-
mulate on, under or around acoustical material, or
on any external surfaces of the air compressor.
Wipe down using an aqueous industrial cleaner or
steam clean as required. If necessary, remove
acoustical material, clean all surfaces and then
replace acoustical material. Any acoustical material
with a protective covering that has been torn or
punctured should be replaced immediately to pre-
vent accumulation of liquids or fluid film within the
material.
DO NOT
use flammable solvents for
cleaning purposes.
D.
Disconnect and lock out all power at source prior
to attempting any repairs or cleaning of the com-
pressor or of the inside of the enclosure, if any.
E.
Keep electrical wiring, including all terminals and
pressure connectors in good condition. Replace
any wiring that has cracked, cut, abraded or other-
wise degraded insulation, or terminals that are
worn, discolored or corroded. Keep all terminals
and pressure connectors clean and tight.
F.
Keep grounded and/or conductive objects such
as tools away from exposed live electrical parts
such as terminals to avoid arcing which might serve
as a source of ignition.
G.
Remove any acoustical material or other materi-
al that may be damaged by heat or that may sup-
port combustion and is in close proximity, prior to
attempting weld repairs.
H.
Keep suitable fully charged Class BC or ABC fire
extinguisher or extinguishers nearby when servic-
ing and operating the compressor.
I.
Keep oily rags, trash, leaves, litter or other com-
bustibles out of and away from the compressor.
J. DO NOT
operate the compressor without proper
flow of cooling air or water or with inadequate flow
of lubricant or with degraded lubricant.
K. DO NOT
attempt to operate the compressor in
any classification of hazardous
environment unless the compressor has been spe-
cially designed and manufactured for that duty.
1.5 MOVING PARTS
A.
Keep hands, arms and other parts of the body
and also clothing away from couplings, fans and
other moving parts.
B. DO NOT
attempt to operate the compressor with
the fan, coupling or other guards removed.
C.
Wear snug-fitting clothing and confine long hair
when working around this compressor, especially
when exposed to hot or moving parts.
D.
Keep access doors, if any, closed except when
making repairs or adjustments.
E.
Make sure all personnel are out of and/or clear
of the compressor prior to attempting to start or
operate it.
F.
Disconnect and lock out all power at source and
verify at the compressor that all circuits are de-
energized to minimize the possibility of accidental
start-up, or operation, prior to attempting repairs or
adjustments. This is especially important when
compressors are remotely controlled.
G.
Keep hands, feet, floors, controls and walking
surfaces clean and free of fluid, water or other liq-
uids to minimize the possibility of slips and falls.
1.6 HOT SURFACES, SHARP EDGES AND SHARP
CORNERS
A.
Avoid bodily contact with hot fluid, hot coolant,
hot surfaces and sharp edges and corners.
B.
Keep all parts of the body away from all points of
air discharge.
C.
Wear personal protective equipment including
gloves and head covering when working in, on or
around the compressor.
D.
Keep a first aid kit handy. Seek medical assis-
tance promptly in case of injury.
DO NOT
ignore
small cuts and burns as they may lead to infection.
1.7 TOXIC AND IRRITATING SUBSTANCES
A. DO NOT
use air from this compressor for respi-
ration (breathing) except in full compliance with
OSHA Standards 29 CFR 1910 and/or any applica-
ble Federal, State or Local codes or regulations.
Death or serious injury can result from inhaling
compressed air without using proper safety
equipment. See OSHA standards and/or any
applicable Federal, State, and Local codes, stan-
dards and regulations on safety equipment.
Summary of Contents for LS16T
Page 6: ......
Page 23: ...Section 2 DESCRIPTION 17 Figure 2 4A Control System Diagram Functional Components...
Page 24: ...Section 2 DESCRIPTION 18 Figure 2 4B Control System Diagram START...
Page 25: ...Section 2 DESCRIPTION 19 Figure 2 4C Control System Diagram MODULATION...
Page 26: ...Section 2 DESCRIPTION 20 Figure 2 4D Control System Diagram FULL LOAD...
Page 27: ...Section 2 DESCRIPTION 21 Figure 2 4E Control System Diagram UNLOAD...
Page 32: ...NOTES 26...
Page 35: ...Section 3 SPECIFICATIONS 29 Figure 3 2 Identification LS16T 100 125 Air cooled 02250138 172R01...
Page 36: ...Section 3 SPECIFICATIONS 30 Figure 3 3 Identification LS16T 150 200 Air cooled 02250134 200R02...
Page 44: ...NOTES 38...
Page 54: ...NOTES 48...
Page 57: ...NOTES 51...
Page 62: ...Section 8 ILLUSTRATIONS AND PARTS LIST 56 02250134 187R00 8 5 AIR INLET SYSTEM...
Page 72: ...Section 8 ILLUSTRATIONS AND PARTS LIST 66 02250134 191R00 8 9 AIR PIPING SYTEM 150 200HP...
Page 74: ...Section 8 ILLUSTRATIONS AND PARTS LIST 68 02250134 191R00 8 9 AIR PIPING SYTEM 150 200HP...
Page 76: ...Section 8 ILLUSTRATIONS AND PARTS LIST 70 02250138 175R01 8 10 FLUID PIPING SYSTEM 100 125HP...
Page 80: ...Section 8 ILLUSTRATIONS AND PARTS LIST 74 02250134 197R00 8 12 DISCHARGE SYSTEM...
Page 82: ...Section 8 ILLUSTRATIONS AND PARTS LIST 76 02250134 197R00 8 12 DISCHARGE SYSTEM...
Page 84: ...Section 8 ILLUSTRATIONS AND PARTS LIST 78 02250134 197R00 8 12 DISCHARGE SYSTEM...
Page 86: ...Section 8 ILLUSTRATIONS AND PARTS LIST 80 02250134 196R00 8 13 CONTROL START SYSTEM...
Page 88: ...Section 8 ILLUSTRATIONS AND PARTS LIST 82 02250134 196R00 8 13 CONTROL START SYSTEM...
Page 90: ...Section 8 ILLUSTRATIONS AND PARTS LIST 84 02250137 724R02 8 14 CONTROL PANEL...
Page 92: ...Section 8 ILLUSTRATIONS AND PARTS LIST 86 02250138 176R00 8 15 ENCLOSURE 100 125HP...
Page 94: ...Section 8 ILLUSTRATIONS AND PARTS LIST 88 02250134 193R00 8 16 ENCLOSURE 150 200HP...
Page 96: ...Section 8 ILLUSTRATIONS AND PARTS LIST 90 8 17 DECAL GROUP...
Page 98: ...Section 8 ILLUSTRATIONS AND PARTS LIST 92 8 17 DECAL GROUP...
Page 100: ...Section 8 ILLUSTRATIONS AND PARTS LIST 94 8 17 DECAL GROUP...
Page 102: ...Section 8 ILLUSTRATIONS AND PARTS LIST 96 8 18 DECAL LOCATIONS OPEN AIR COOLED...
Page 104: ...Section 8 ILLUSTRATIONS AND PARTS LIST 98 8 19 ENCLOSURE DECALS...
Page 106: ...Section 8 ILLUSTRATIONS AND PARTS LIST 100 8 20 DECAL LOCATIONS CONTROL BOX...
Page 110: ...NOTES 104...
Page 111: ......