Section 5
OPERATION
25
5.2 PURPOSE OF CONTROLS
CONTROL OR INDICATOR
PURPOSE
PRESSURE RELIEF VALVE
Opens sump pressure to the atmosphere should
pressure inside the sump become too high (150 psig
[10.3 bar]). Operation of this valve indicates that the
high pressure switch is either faulty or out of adjust-
ment.
SULLICON CONTROL
Regulates the amount of air allowed to enter the air in-
let valve. This regulation is determined by the amount
of air being used at the service line.
PRESSURE REGULATOR --- SULLICON
Opens a pressure line between the sump and Sul-
licon Control allowing the Sullicon Control to regulate
air delivery according to the air demand.
PRESSURE REGULATOR--- SPIRAL VALVE
Opens a pressure line between the service line and
the spiral valve actuator allowing the spiral valve to
regulate air delivery according to air demand.
SOLENOID VALVE #1
Bypasses the pressure regulator valve causing the
Sullicon Control to close the inlet valve when the
compressor reaches maximum operating pressure.
SOLENOID VALVE #2 (spiral valve control)
Opens when the compressor starts; closes when the
compressor is shut off. This prevents any air system
loss when the compressor is shut off.
LINE PRESSURE TRANSDUCER (P2)
Senses service line pressure. When line pressure
reaches maximum setting, the Supervisor signals the
solenoid valve to OFF LOAD the compressor. The
message “ON LOAD” or “OFF LOAD” will be dis-
played to indicate the status of the control. P2 is also
used to calculate separator differential pressure
∆
P1.
BLOWDOWN VALVE
Vents sump pressure to the atmosphere during un-
load conditions and shutdown.
WATER REGULATING VALVE
Regulates the amount of cooling water used in the
(water---cooled only)
cooler to keep the compressor running at a normal
operating temperature.
5.3 INITIAL START---UP PROCEDURE
The following procedure should be used to make
the initial start---up of the compressor:
1. Read the preceding pages of this manual thor-
oughly.
2. Be sure that all preparations and checks de-
scribed in the Installation Section have been
made.
3. Crack open the shut off valve to the service line.
WA R N I N G
!
Be sure that the depressurization line between
the sump and the air---cooled cooler package is
connected as explained in Section 4 (Paragraph
4.4).
4. Set the compressor in MANUAL mode and start
the compressor by pressing the ON/OFF pad.
5. Check for possible leaks in piping.
6. Slowly close the shut---off valve and check that
the maximum pressure (P2) and pressure differ-
ential (P2) are correctly programmed.
7. Observe the operating temperature. If the oper-
ating temperature exceeds 205
_
F (96
_
C), the
cooling system or installation environment
should be checked.
8. Observe return line sight glasses and mainte-
nance indicators.
9. Open shut---off valve to service line.
10. Reinspect the compressor for temperature and
leaks the following day.
Summary of Contents for LS-25S
Page 12: ...Section 2 DESCRIPTION 7 Figure 2 3 Compressor Piping and nstrument Diagram...
Page 16: ...Section 2 DESCRIPTION 11 Figure 2 5A Control System Diagram Start Full Load...
Page 17: ...Section 2 DESCRIPTION 12 Figure 2 5B Control System Diagram Modulation Unload...
Page 49: ...Section 7 ILLUSTRATIONS AND PARTS LIST 44 7 4 COMPRESSOR AIR INTAKE SYSTEM...
Page 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 10 COMPRESSOR DISCHARGE SYSTEM...
Page 73: ...Section 7 ILLUSTRATIONS AND PARTS LIST 68 7 10 COMPRESSOR DISCHARGE SYSTEM...
Page 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 12 COMPRESSOR ACTUATOR...
Page 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 13 ELECTRO PNEUMATIC CONTROL SYSTEM...
Page 83: ...Section 7 ILLUSTRATIONS AND PARTS LIST 78 7 13 ELECTRO PNEUMATIC CONTROL SYSTEM...
Page 85: ...Section 7 ILLUSTRATIONS AND PARTS LIST 80 7 14 ENCLOSURE...
Page 87: ...Section 7 ILLUSTRATIONS AND PARTS LIST 82 7 14 ENCLOSURE...
Page 89: ...Section 7 ILLUSTRATIONS AND PARTS LIST 84 7 15 UNIT TUBING...
Page 91: ...Section 7 ILLUSTRATIONS AND PARTS LIST 86 7 16 DECAL GROUP 1 2 3 4 5 6 7 8 9 10...
Page 95: ...Section 7 ILLUSTRATIONS AND PARTS LIST 90 7 16 DECAL GROUP 21 22 23 24 25...
Page 97: ...Section 7 ILLUSTRATIONS AND PARTS LIST 92 7 16 DECAL GROUP 26 28 29 30 31...
Page 102: ...Section 7 ILLUSTRATIONS AND PARTS LIST 97 7 20 WIRING DIAGRAM...
Page 103: ...Section 7 ILLUSTRATIONS AND PARTS LIST 98 7 21 WIRING DIAGRAM WYE DELTA...