SECTION 6
ES-6 USER MANUAL
73
F
OR
D
IFFERNTIAL
A
DJUSTMENT
OF
A
IR
P
RESSURE
S
WITCH
Differential is the difference between the high and
low pressure settings.
Turning the screw clockwise increases the
differential, and counterclockwise decreases the
differential pressure.
U
NLOADER
S
OLENOID
V
ALVE
M
AINTENANCE
Unloader valve maintenance is minimal, but a
periodic cleaning is desirable. The time between
cleanings will vary depending on operating
conditions. In general, if the voltage to the coils is
correct, sluggish valve operation or excessive
leakage will indicate that cleaning is required.
It is not necessary to remove the valve from the pipe
line for repairs.
D
ISASSEMBLY
AND
R
EASSEMBLY
1. Remove the retaining cap and slip the entire
solenoid off the solenoid base subassembly.
2. Unscrew the solenoid base assembly.
Remove the core assembly, core spring and
body gasket.
3. All parts are now accessible for cleaning or
replacement.
4. Reassemble in reverse order of disassembly.
CO
IL
R
EPLACEMENT
1. Remove the retaining cap, nameplate and
cover.
2. Slip the yoke containing the coil and sleeves
off the solenoid base subassembly.
3. Reassemble in reverse order of disassembly.
I
NLET
C
ONTROL
V
ALVE
. The only parts which normally
require replacement are the piston seal on the intake
valve piston and gasket. Follow this procedure for
inlet control maintenance.
DANGER
DO NOT touch the electrical contacts, ter-
minal or leads with any part of the body or
any uninsulated metallic object.
Severe electrical shock may occur.
WARNING
Turn off all power, relieve sump pressure,
and disconnect coil lead wires to the
solenoid valve before making repairs.
WARNING
Before doing compressor maintenance,
disconnect compressor from power source
and lock out power source. Isolate
compressor from line pressure by closing
recommended discharge shut-off valve and
releasing all internal pressure from
compressor.
Table 6-2: Modulating Control Pressure Settings
PRESSURE SWITCH SETTING
250025-299
MODULATING CONTROL VALVE 250017-280
Rising Pressure (PSIG/BAR)
Falling Pressure (PSIG/BAR)
Press Switch
Opening PSIG/
BAR
Press Switch
Closing PSIG/
BAR
Start Unloading
Fully Unloaded
Start Unloading
Fully Unloaded
100/6.9
70/4.8
87/6
95/6.6
93/6.4
85/5.9
125/8.6
95/6.6
112/7.7
120/8.3
118/8.1
110/7.6
150/10.3
120/8.3
137/9.4
145/10
143/9.9
135/9.3
175/12.1
145/10
162/11.2
170/11.7
168/11.6
160/11
Summary of Contents for ES-6 10H
Page 1: ......
Page 6: ...TABLE OF CONTENTS...
Page 12: ...NOTES 12...
Page 18: ...18 NOTES...
Page 23: ...23 NOTES...
Page 26: ...ES 6 USER MANUAL SECTION 3 26 3 6 IDENTIFICATION ES 6 STANDARD WITH ENCLOSURE 02250172 316 R00...
Page 52: ...ES 6 USER MANUAL SECTION 3 52 3 19 WIRING DIAGRAM DUAL CONTROL WYE DELTA 02250058 093 R04...
Page 54: ...ES 6 USER MANUAL SECTION 3 54 3 20 WIRING DIAGRAM SRS 25 100 115 230V 1 60 02250171 733 R00...
Page 56: ...ES 6 USER MANUAL SECTION 3 56 3 21 WIRING DIAGRAM SRS 9 18 220 240V 1 50 02250171 738 R00...
Page 58: ...ES 6 USER MANUAL SECTION 3 58 3 22 WIRING DIAGRAM SRS 24 30 220 240V 1 50 02250171 739 R00...
Page 60: ...60 NOTES...
Page 78: ...78 NOTES...
Page 82: ...82 NOTES...
Page 83: ...NOTES 83...
Page 84: ......